The PURO GRAND Condensate Cleaner
Installation instructions:
The PURO GRAND condensate cleaner has been specially developed to separate oil from condensate extracted from compressed air systems and is
effective with all types and makes of compressors, oils and drain valves.
To obtain the best performance from the machines, we suggest the following:
Installation instructions:
1) The unit is designed to easily fit against a wall. Position the machine with the TEST to the front and remove the lids from the top of both
vessels.
2) After ensuring that no harmful pressure exists, connect the condensate inlet pipe(s) using the 1/2"
"
inlet connections. If only one connection is
used, the others can be sealed with a screwed plug. Do not over-tighten connections.
3) Connect the 1/2" outlet connection to a suitable sewage drain. Do not over-tighten connections.
4) Lift the poly-element from vessel (1) and place it to one side for the time being.
5) Remove the plastic packing material from the activated carbon element and slide it back in to the vessel (2) and let it rest on the bottom of the
vessel. Place the closed lid on vessel (2).
6) Remove the depressuriser foam pad, pour clean water into the depressuriser box until it flows from the outlet pipe and then replace the foam
pad into the depressurising box.
7) With the cable-tied end upwards, replace the white poly-element into vessel (1) by slowly pushing the element down into vessel 1
(the poly-element should rest on the bottom of vessel 1).
8) Place lid 1 on vessel 1.
9) Your condensate cleaner is now ready for use.
Note: During initial filling, dust may rise from the carbon elements; this is only displaced air and is entirely harmless. We recommend the active
carbon element to be pre-soaked for 24 hrs. Any carbon dust in the outlet water is harmless.
We recommend that initially a daily check is made on the quality of the output from your condensate cleaner. After a day or so, the output should be
clear when viewed in a clear glass container.
We recommend that you use our protection clothing kit when installing and or servicing the condensate cleaner.
Maintenance instructions:
Used elements can be heavy and we strongly advise that normal precautions for the lifting of heavy weights are taken.
To replace the poly-element, remove the lid from the top of the vessel (1) and lift the used poly-element out of the vessel. Simply lower the new
poly-element slowly into the vessel (1) and let it rest on the bottom of vessel 1.
To change carbon elements, remove a carbon element from its vessel (2) after removing the lid, lift the used carbon element from the vessel and
place where the draining water will cause no harm. Slide the new carbon element into the vessel (2) until it rests on the bottom of the vessel. The top
of the carbon element should be below the outlet hole. If required, clean water can be poured onto the top of the carbon element to prevent dust.
All used elements must be properly disposed of in accordance with current regulations for the disposal of hazardous waste in your area.
Question and Answer IconNeed help?

Do you have a question about the Jorc PURO GRAND and is the answer not in the manual?

Summary

Installation Instructions

Unpack the Unit

Unpack the PURO GRAND condensate cleaner unit from its packaging.

Remove Lids

Remove the lids from the top of both vessels of the unit.

Prepare Carbon Element

Remove and unwrap the carbon element before placing it into vessel (2).

Install Carbon Element

Slide the carbon element into vessel (2) and let it rest on the bottom.

Replace Lid on Vessel 2

Replace the lid on tower number 2 and include the test kit for future reference.

Remove Poly Element

Remove the poly-element from vessel (1) for preparation.

Connect Inlet Pipes

Connect the condensate inlet pipes using the 1/2" inlet connections.

Connect Outlet Pipe

Connect the 1/2" outlet connection to a suitable sewage drain.

Prepare Depressuriser Box

Remove foam padding, fill with clean water, and replace padding.

Close Test Valve

Ensure the test valve is closed by turning it to the right.

Install Poly Element

Push the white poly-element slowly into vessel (1) until it rests on the bottom.

Replace Lid on Vessel 1

Replace the lid (1) back onto vessel 1.

Maintenance Instructions

Replace Poly Element

Remove lid, lift old poly-element, and lower new one into vessel (1).

Replace Carbon Element

Remove lid, lift old carbon element, and insert new one into vessel (2).

Disposal of Used Elements

Dispose of all used elements according to local hazardous waste regulations.

Feature Instructions

Overflow Indicator

The overflow indicator raises if fluid input is too high or blockage occurs.

Test Bottle Kit

Use test kit to check output fluid oil content by comparing shading to label.

Draining the Unit

Connect a hose to the service drain to empty the unit for maintenance.

Jorc PURO GRAND Specifications

General IconGeneral
Tank Capacity750 ml
Ultrasonic Frequency42 kHz
Power50 W
Timer Settings90, 180, 280, 380, 480 s