EasyManuals Logo

Jøtul 620 Series User Manual

Jøtul 620 Series
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #44 background imageLoading...
Page #44 background image
44
6.4 Sweeping ue pipes to the
chimney
Flue pipes must be swept through the ue pipe sweeping
hatch or through the door opening.
6.5 Inspection of the replace
Jøtul recommends that you carefully inspect your replace
yourself after it has been swept/cleaned. Check all visible
surfaces for cracks. Also check that all joints are sealed
and that the gaskets are in the correct position. Any gaskets
showing signs of wear or deformation must be replaced.
Thoroughly clean the gasket grooves, apply ceramic glue
(available from your local Jøtul dealer) and press the gasket
well into place. The joint will dry quickly.
6.6 Exterior maintenance
Painted products may change colour after several years’
usage. The surface should be cleaned and brushed free of
any loose particles before new paint is applied.
7.0 Operational problems -
troubleshooting
Poor draught
Check the length of the chimney and that it complies with
national laws and regulations. (See also «2.0 Technical data»
). Make sure that the minimum cross section on the chimney is
according to «2.0 Technical data» in the installation manual.
Make sure that there is not anything preventing the smoke
gasses from escaping: branches, trees, etc.
Upon suspicion of excessive/poor draught in the chimney,
seek professional help for measurement and adjustment.
The re extinguishes after a while
Make sure that the rewood is suf ciently dry.
Find out whether there is negative pressure in the house,
close mechanical fans and open a window close to the
replace.
Check that the air vent is open.
Check that the ue outlet is not clogged by soot.
Unusual amount of soot accumulates on
the glass
Some soot will always stick to the glass, but the quantity
depends on:
Moisture in the fuel.
The local draught conditions.
Air vent opening.
Most of the soot will normally burn off when the air vent is
opened all the way and a fire is burning briskly in the fireplace.
(See «6.1 Cleaning the glass».)
8.0 Optional extras
8.1 Leg Rack
Item no. 51052512
8.2 Sheet metal grid
Sheet metal grid Jøtul I 620 Series
Item no. 50051752
8.3 Outside air connection
Ø 80 mm, art. nr. 51047509
Ø 100 mm, art. no. 51012164
9.0 Recycling
9.1 Recycling packaging
Your replace is delivered with the following packaging:
A wooden pallet that can be cut up and burned in the
replace.
Cardboard packaging that should be taken to a local
recycling facility.
Plastic bags that should be taken to a local recycling facility.
9.2 Recycling the replace
The replace is made of:
Metal that should be taken to a local recycling facility.
Glass that should be disposed of as hazardous waste.
The glass in the replace must not be placed in a regular
source segregation container.
Vermiculite burn plates that can be disposed of in regular
waste containers.
ENGLISH

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jøtul 620 Series and is the answer not in the manual?

Jøtul 620 Series Specifications

General IconGeneral
MaterialCast Iron
Maximum Log Length18 inches
Flue Outlet6 inches
Emissions CertificationEPA Certified
TypeWood Stove
Efficiency75%
Emissions2.5 g/h
FinishBlack matte

Related product manuals