Jøtul F 371 ADVANCE User Manual

Jøtul F 371 ADVANCE
25 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
4
Technical data in acc. with EN 13240 / NS 3058
Nominal heat output: 6,0 kW
Flue gas volume: 6,3 g/s
Chimney draught, EN 13240: 12 Pa
Recommended negative pressure
in smoke outlet: 14-16 Pa
Ef ciency: 78%@6,8 kW
CO emissions (13% O
2
): 0.06%
CO emissions (13% O
2
): 731 mg / Nm
3
NOx at 13% O
2
: 93 mg / Nm
3
OGC @ 13 % O
2
: 45 mg/Nm
3
Air consumption: 6,1 litre/sec or 22 m
3
/h
Chimney temperature, EN 13240: 275
o
C
Dust: <4 mg/Nm
3
@13%O
2
Particle emission NS 3059: 2,9 g / kg
Type of fuel: Wood
Recommended log length: 27-30 cm
Max. log length: 33 cm
Fuel consumption: 2.1 kg/h
Max. kindling amount: 2.0 kg
Nominal kindling amount: 1.6 kg
Operation: Intermittent
Intermittent combustion in this context means normal use of the
fireplace, i.e. fuel is added as soon as the fuel has burnt down to
a suitable amount of embers.
3.0 Safety
NB! To guarantee optimal performance and safety, Jøtul
recommends that its stoves are tted by a quali ed
installer (see www.jotul.com for a complete list of dealers).
Any modi cations to the product may result in the product
and safety features not functioning as intended. The same
applies to the installation of accessories or optional extras not
supplied by Jøtul. This may also be the case if parts that are
essential to the functioning and safety of the replace have
been disassembled or removed.
In all these cases, the manufacturer is not responsible or liable
for the product and the right to make a complaint becomes null
and void.
The Clean Air Act
“The Clean Air Act 1993 and Smoke Control Areas”
Under the Clean Air Act local authorities may declare the
whole or part of the district of the authority to be a smoke
control area. It is an offence to emit smoke from a chimney of
a building, from a furnace or from any xed boiler if located in a
designated smoke control area. It is also an offence to acquire
an “unauthorised fuel” for use within a smoke control area
unless it is used in an “exempt” appliance (“exempted” from
the controls which generally apply in the smoke control area).
In England appliances are exempted by publication on a list
by the Secretary of State in accordance with changes made to
sections 20 and 21 of the Clean Air Act 1993 by section 15 of
the Deregulation Act 2015. Similarly in Scotland appliances are
exempted by publication on a list by Scottish Ministers under
section 50 of the Regulatory Reform (Scotland) Act 2014.
In Northern Ireland appliances are exempted by publication
on a list by the Department of Agriculture, Environment and
Rural Affairs under Section 16 of the Environmental Better
regulation Act (Northern Ireland) 2016.
In Wales appliances are exempted by regulations made by
Welsh Ministers.
Further information on the requirements of the Clean Air Act
can be found here: https://www.gov.uk/smoke-control-area-
rules
Your local authority is responsible for implementing the Clean
Air Act 1993 including designation and supervision of smoke
control areas and you can contact them for details of Clean Air
Act requirements.
The Jøtul F 371 Advance, Jøtul F 371 Advance HT, Jøtul F
373 Advance, Jøtul F 377 Advance, Jøtul F 377 Advance,
Jøtul F 377 Advance HT, Jøtul F 378 Advance and Jøtul F 378
Advance HT have been recommended as suitable for use in
smoke control areas when burning wood logs.
3.1 Fire Prevention Measures
There is a certain element of danger every time you use
your replace. The following instructions must therefore be
followed:
The minimum safety distances when installing and using
the replace are given in g. 1. The speci ed distance to
ammable materials, applies to this stove. The stove must
be installed with a CE approved ue. The distance of the
ue pipe to combustible materials must also be observed.
Ensure that furniture and other ammable materials are not
too close to the replace. Flammable materials should not
be placed within 1100 mm of the replace.
• Allow the re to burn out. Never extinguish the ames with
water.
• The replace becomes hot when lit and may cause burns
if touched.
Only remove ash when the replace is cold. Ash can contain
hot embers and should therefore be placed in a non-
ammable container.
Ash should be placed outdoors or be emptied in a place
where it will not present a potential re hazard.
In case of chimney re:
Close all hatches and vents.
• Keep the rebox door closed.
Check the loft and cellar for smoke.
• Call the re service.
• Before use after a re an expert must check the replace
and the chimney in order to ensure that it is fully functional.
3.2 Floor
Foundation
You need to make sure the foundation is suitable for a replace.
See “2.0 Technical Data” for speci ed weight.
We recommend the removal of any ooring that is not attached
to the foundation (“ oating oors”) beneath the installation.
Requirements for protection of wooden
ooring beneath the replace
Jøtul F 370 Advance Series has a heat shield underneath
which protects the base from radiation. The product has
an integrated oor protection and may therefore be placed
directly on a wooden oor.
Jøtul recommends that any ooring made of combustible
material, such as linoleum, carpets, etc. should be removed
from under the oor plate.
ENGLISH

Other manuals for Jøtul F 371 ADVANCE