EasyManua.ls Logo

joule DIRECT - Specification Summary

joule DIRECT
17 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
unvented hot water cylinders
installation and maintenance instructions
Page 15 / 17
SPECIFICATION SUMMARY
MATERIALS
- Inner shell - Duplex Stainless Steel
- Coil - Stainless Steel AISI 316L
- Bosses - Stainless Steel AISI 316L
- Every cylinder is water tested to a pressure of 10bar.
INSULATION
- Fire retardant polyurethane foam
- The foam is CFC-Free and HCFC-Free.
- The foam has an Ozone Depletion Potential of Zero and a Global Warming Potential of 2.8
CASEWORK
- Electrostatically painted steel
ANODE
- None fitted/none required
EXPANSION VESSEL
CONTROL SETTINGS
- Pressure Reducing Valve - 3 Bar
- Expansion Relief Valve - 6 Bar
- Pressure and Temperature Relief Valve - 7 Bar/90°C
- High Limit Thermostat in Dual Thermostat
- High Limit Thermostat in Immersion Heater
IMMERSION HEATER
- 1¾” BSP Parallel Threaded Head
- Long Life Incoloy Sheathed Low Noise Element 14”
- Long Long Life Incoloy Sheathed Thermostat Pocket
- Brazed Construction
- Combined Thermostat and Safety Cutout
- Element Rating 3kW at 240V A/C