5-30
JMA-9100/7100 Installation Manual > 5.OPTION UNIT > 5.2 INSTALLATION OF POWER CONTROL UNIT
Fig 5-29: JMA-7122-9XA (w/ NQE-3167) desktop
NJU-85
PERFORMANCE UNIT
250V-MPYCYS -7
250V-TTYCS-1
3C-2V x5 (MAX 30m)
250V-TTYCS-1
18 CORES COMPOSITE CABLE
H-2695111153
MAX 18.0φ (JRC SUPPLY)
250V-TTYCS-4
H-2695110006 (JRC SUPPLY )
H-7ZCNA0483 (JRC SUPPLY)
250V-MPYC-4
250V-TTYCS-4
250V-TTYCS-4
GYRO
LOG
(NMEA 0183)
DGPS
VDR
RADAR
(INTER SWITCH)
ECDIS
(JAN-901M)
ALERM MONITORING SYSTEM
(NE AREST APPROACH)
(PO WE R FAIL)
CONNING DISPLAY
(JAN-701-CON )
AIS
0.6/1kV-DPYCYS -6
0.6/1kV-DPYCYS -1.5
SHIP’S MAIN
AC220 V ,60 Hz,1 φ,800 VA
SHIP’S MAIN
for POWER FAIL ALARM
DC24V(BATTERY),1W
NOTE: ELIMINATING THE INTERFERENCE ON FREQUENCIES USED FOR MARINE COMMUNICATIONS AND
NAVIGATION DUE TO OPERATION OF THE RADAR.
ALL CABLES OF THE RADAR ARE TO BE RUN AWAY FROM THE CABLES OF RADIO EQUIPMENT.
(ex. RADIOTELEPHONE, COMMUNICATIONS RECEIVER and DIRECTION FINDER. etc..)
ESPECIALLY INTER-WIRING CABLES BETWEEN SCANNER UNIT AND DISPLAY UNIT OF THE RADAR
SHOULD NOT BE RUN PARALLEL WITH THE CABLES OF RADIO EQUIPMENT.
(X-BAND 25kW RADAR)
JMA-7122-9XA形レーダー総合系統図
GENERAL SYSTEM DIAGRAM OF RADAR TYPE JMA -7122 -9XA
(WITH PM UNIT)
NKE-1125-9
SCANNER UNIT
NWZ-173
MONITOR UNIT
NCE-5163
OPERATION UNIT
H-7 Z C RD1338
Power & Contr ol Cable
DVI CABLE
CONTROL CABLE
POWER CABLE
(JRC SUPPLY) max 5m
(5A)
NBL-175
0.6/1kV-DPYCYS-1.5
SHIP’S MAIN
for HEATER
AC220 V, 60Hz,1 φ
AC100 V,60Hz
1φ,200 W
CIRCUIT BREAKER
(SHIP YARD SUPPLY)
0.6/1kV-DPYCYS-1.5
STEPDOWN
TRANSFORMER
NQE-3167
POWER CONTROL UNIT
14 CORES COMPOSITE CABLE
H-2695110056
MAX 23φ (JRC SUPPLY)
0.6/1kV-DPYCY-6
SHIP’S MAIN
AC220V,60Hz,1φ, 400V A
14 CORES COMPOSITE CABLE
H-2695110056
MAX 23φ (JRC SUPPLY)
400m MAX
COAXIAL CABLE for VIDEO
RG-10/UY (JRC SUPPLY)
400m MAX
NDC-1399-7
RADAR PROCESS UNIT
NCD-4790T DISPLAY UNIT
注) レーダーの動作が他の無線装置に、雑音妨害を与えることを防止するために、レーダーケーブルを他の無線
装置のケーブルから極力離して敷設して下さい。特に、空中線ケーブルを他の無線装置のケーブルと平行に
敷設しないで下さい。
OPTION