(5) Check with Performance Monitor
The transmitted power and the receiving sensitivity can be checked relatively using the
Performance Monitor. For the operating procedures of the Performance Monitor, refer to
Operation of Performance Monitor in Section 3.4 BASIC OPERATIONS.
(6) Error Logging Display
If any system error occurs, the communication line in which the error is caused will be
indicated by the selected characters. The errors that are released will also be indicated in
time sequence.
1 Press .
The TEST Menu will appear.
2 Press .
The ERROR LOGGING Menu will appear and the location in which an error has occurred will
appear by selected characters.
TEST MENU
0.
EXIT
ERROR LOGGING
1.
ALL CLEAR
6
TEST
Procedures