1 . Specifications
Operating frequency
bands
:1.8 MHz band 1.800 to 2.000 · MHz
3.5 MHz band 3.500 to 4.000 MHz
7 MHz band 7.000 to 7.300 MHz
10 MHz band 10.100 to 10.150 MHz
14 MHz band 14.000
to
14.350 MHz
18
MHzband
18.068
to
18.168 MHz
21
MHz band 21.000
to
21.450 MHz
24 MHz band 24.890
to
24.990 MHz
28 MHz band 28.000 to 29.700 MHz
Rated output power :SSB 1
kW
PEP* 1 00% duty cycle; 24 hour.
CW 1
kW*
1 00% duty cycle, 24 hour.
FSK/SSTV 1 kW* 100% duty cycle, 1/4 hour.
Output impedance
:50
Q unbalanced, VSWR 3.0 (16.7
to
150
Q)
Harmonics :-60
dB
or less
Intermodulation
distortion
(IMD)
:-35
dB
or less below
PEP
(at 1
kW
output)
Input impedance
:SOQ
unbalanced
Exciting power
:1
OOW
max.
Frequency switching
time : Less than
0.1
sec.
Power supply valtage :
85
to 264 V
AC,
single-phase
Power consumption :2.5 kVA or less (at 1 kW output)
Input power factor :95% or more (at 1 kW output)
Temperature range :-1
ooc
to
40°C
Protection circuits :PA excess current;
PA
overheat;
PA
abnormal Ioad;
AC
power supply excess valtage; power supply overheat;
PA
failure; excessive antenna VSWR; exciting power
excess; and antenna matehing anomaly.
Dimensions :430(W) X 300(h) X 402(0)
mm
Weght : Approx. 28Kg
* Note :Rated output on 200 to 240V AC. The rated output power on 1 00 to 120V AC is 750W PEP.
3