blower.
12. If you are ready to build housing for the module, please contact us for 3D file of the
module you’re using and confirm your drawing with our hardware engineer. And if possible,
please send us your SOP of assembly to check ifthere is any risk.
13. Pay attention to the heat dissipation. Reserve a certain space for module heat dissipation
when the module is integrated into the device.
14. Glue dispensing and gluing are not recommended at the joint between the optical part of
U module and PCB.
15. It’s recommended that the module is assembled in the same direction as it was made, that
is, right side up. Generally, the side with small label is the up side, and please pay attention to
the pitch adjustment during installation.
16. If the housing have a need of IP67 protection or above, anti-reflective glass is
recommended before lens. The light transmittance should be over 90% and the more the better.
Please notice that any glasses before the lens could lower the performance.
17. The module can be used continuously, in this case, 3000~5000 hours of use time is
guaranteed.
18. If you have any problems or questions during the test, please take photos or videos and
give detailed description to us, the more information sent, the faster respond can be
supplied. If you receive any error code during test, please check it with the error code list in
the manual. If the error code is not listed, please contact us.