Do you have a question about the Jun-Air 2xOF302-40BD2 and is the answer not in the manual?
Follow safety measures to prevent electric shock during operation and maintenance.
Adhere to warnings to avoid electrocution, especially regarding unattended use and water contact.
Understand dangers associated with combustible liquids, explosive atmospheres, and open flames.
Take caution to avoid injury from compressed air, hot surfaces, and moving parts.
Guidelines for connecting AC motors, emphasizing earthing and voltage compatibility.
Guidelines for connecting DC motors, focusing on polarity and motor protection.
Procedure to set the maximum pressure cut-out using the designated adjustment screw.
Procedure to set the cut-in pressure using the differential adjustment screw.
Steps to diagnose and resolve issues when the compressor does not start.
Troubleshooting for buzzing sounds, often indicating pressure-related startup problems.
Steps to fix vacuum pumps that fail to achieve sufficient vacuum, checking components.
| Model | 2xOF302-40BD2 |
|---|---|
| Series | OF302 |
| Type | Oil-free |
| Number of Compressors | 2 |
| Number of Stages | 2 |
| Max Pressure | 8 bar |
| Voltage | 230V/50Hz |
| Tank Size | 40 L |
| Noise Level | 60 dB(A) |