Hangzhou Junce Instruments Co., Ltd.
12
B. Main interface operation
Click the title of the main interface to enter the main interface of the APP.
a. Output state control switch
Click the "Output state control switch" to control the output state, and
different states will be displayed under different protection states, as shown in
Figure 3-1-10, the output state is off, and Figure 3-1-11 over voltage protection
state.
b. Voltage fine adjustment
Click the voltage value, the "Input:Voltage calibration" pop-up box will pop
up, enter the corresponding value for fine-tuning, the default voltage calibration
is 100. As shown in Figure 3-1-12 below
c. Current fine adjustment
Click the value of the current, the "Input:Current calibration" pop-up box
will pop out, enter the corresponding value for fine-tuning, the default current
calibration is 100. As shown in Figure 3-1-13current calibration.
d. Voltage range
Click on the voltage dial to pop up the pop-up box "input voltage range",
enter the corresponding value, you can adjust the scale range of the voltage
dial, as shown in Figure 3-1-14 Voltage scale range.
e. Current scale maximum value
Click the current dial to pop out the pop-up box "Enter the maximum
current value", enter the correct value, you can adjust the maximum scale
value of the current dial, as shown in Figure 3-1-15 Current scale maximum
value.
f. Clear data
Click the Clear data button, and the "Clear accumulated data" pop-up box
will pop out. After clicking OK, reset the time, power consumption, and
accumulated capacity, as shown in Figure 3-1-16.
g. Percentage of remaining capacity
Click the battery icon, the "Input:Percentage of remaining capacity"
pop-up box will pop out, enter the corresponding value, click OK to complete
the modification, as shown in Figure 3-1-17 remaining capacity percentage.
After using or replacing the battery for the first time, the capacity value
displayed by the volt-ampere meter is not the actual value of the battery, and
capacity setting is required.
h. Preset battery capacity
Click the setting button to the right of the preset battery capacity, the
"Input:Preset battery AH. value" pop-up box will pop out, enter the
corresponding value, click OK to complete the modification, as shown in Figure
3-1-18 to preset the battery capacity.
It is necessary to correctly set the effective capacity of the battery and the

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JUNCTEK KL110F and is the answer not in the manual?

JUNCTEK KL110F Specifications

General IconGeneral
BrandJUNCTEK
ModelKL110F
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals