Hangzhou Junce Instruments Co., Ltd.
28
multiple
60
Set the
percentage of
remaining
battery
capacity
:W60=1,51,50,
The remaining battery capacity
percentage is 50%
61
Zero current
:W61=1,2,1,
Perform zero current
62
Clear
accumulated
data
:W62=1,2,1,
Perform clear accumulated
data
(3) R Command
The R command is a read command, and its command format is
basically the same as the write command format, and the description will
not be repeated here. The data returned by the following machine is just
an example.
Read
PC send
Receive
Read instruction
Read
basic
information
:R00=1,2,1,
:r00=1,47,1120,1
00,101,
1: Communication address;
47: Checksum;
The first 1: Hall sensor (1-Hall
sensor, 2-sampler) in 1120,
the second 1: 100V, 20: 200A;
100: 1.00 version;
101: machine serial number;
Read all
measured
values
:R50=2,2,1,
:r50=2,215,2056,
200,
5408,4592,9437,
14353,
134,0,0,0,162,30
682,
2: Communication address;
215: Checksum;
2056: Voltage, 20.56V;
200: Current ,2.00A;
5408: The remaining battery
capacity is 5.408Ah;
4593: The cumulative
capacity is 4.593Ah;
9437: The watt-hour is
0.09437kw.h;
14353: The running time is
14353s;
134: The ambient temperature
is 34°C;
0: Delegate function to be
determined;
0: The output status is ON;
(0-ON, 1-OVP, 2-OCP, 3-LVP,
4-NCP,
5-OPP, 6-OTP, 255-OFF)