Hangzhou Junce Instruments Co., Ltd.
29
0: Current direction, the
current is forward current;
(0-forward, 1-reverse)
162: Battery life is 162
minutes;
30682: The internal resistance
of the battery is 306.82mΩ;
Read all
set values
:R51=1,2,1,
:r51=1,211,3000,
100,2000,
2000,10000,151,
10,7,200,
120,90,101,0,0,2,
12,13,
1: Communication address;
211: Checksum;
3000: Over-voltage protection
is 30.00V;
100: Under-voltage protection
is 1.00V;
2000: The forward
over-current protection is
20.00A;
2000: Negative over-current
protection is -20.00A;
10000: Over power protection
is 100.00W;
151: Over temperature
protection is 51;
10: The protection recovery
time is 10s;
7: The delay time is set to 7s;
200: The preset battery
capacity is 20.0Ah;
120: 20 fine-tuning factors of
the voltage calibration ;
(100: fine-tuning 0)
90: -10 fine-tuning factors of
the current calibration;
(100: fine-tuning 0)
101: Temperature calibration
increased by 1;
(100: fine-tuning 0)
0: reserved setting (coming
soon);
0: The relay type is normally
open;
(0-normally open relay,
1-normally closed relay)
2: The current multiple is 2;
12: The voltage curve scale is