Universal dimming actuator, 1-gang, 2-gang, 4-gang
Universal dimming actuator, 1-gang
Art. no.: 3901 REGHE
Universal dimming actuator, 2-gang
Art. no.: 3902 REGHE
Universal dimming actuator, 4-gang
Art. no.: 3904 REGHE
Operating instructions
1 Safety instructions
Electrical devices may only be mounted and connected by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage. The load
is not electrically isolated from the mains even when the output is switched off.
Risk of destruction of the dimmer and load if the set operating mode and load type do not
match. Set the correct dimming principle before connecting or exchanging the load.
Fire hazard. For operation with inductive transformers, each transformer must be fused on the
primary side in accordance with the manufacturer's instructions. Only safety transformers ac-
cording to EN 61558-2-6 may be used.
These instructions are an integral part of the product, and must remain with the end customer.
The connected load and dimmer quality on LED lamps are dependent on the type of lamp
and installation conditions. The connected load of the specified values could vary. We
cannot assume any guarantee for proper function, dimming results and dimming quality.
2 Device components
Figure1: View of dimming actuator 2-gang
1 / 16
82575363 04.12.2019
J0082575363

Questions and Answers

  • C
    charlesandrewAug 18, 2025
    Why are all my Jung Lighting Equipment outputs off and not possible to switch on?
    • M
      Michael CannonAug 18, 2025
      If none of the outputs can be switched on, there may be a bus voltage failure. In this case, check the bus voltage. Alternatively, there may be a mains voltage failure, so check the mains voltage on the outputs and mains power supply.
  • K
    Kevin FitzgeraldAug 20, 2025
    What to do if connected LED lamps or compact fluorescent lamps flicker with Jung Lighting Equipment?
    • C
      Carmen HaleAug 20, 2025
      If connected LED lamps or compact fluorescent lamps flicker, it could be due to several reasons. First, check the manufacturer's instructions to ensure the lamps are dimmable. If they are, the dimming principle and lamps may not optimally match, so try exchanging the lamps for another type. For HV-LED, check operation in another dimming principle, reduce connected load as well if necessary. For LV-LED, check the lamp operating device and replace as necessary. With the 'Universal' setting: Define the dimming principle manually.
  • J
    John OlsonAug 26, 2025
    Why do my luminaires flicker or buzz and proper dimming is not possible with my Jung Lighting Equipment?
    • T
      thuffAug 26, 2025
      If luminaires flicker or buzz, proper dimming is not possible, and the device buzzes, it may be due to a wrong dimming principle being set. In this case, disconnect the device and luminaire, and switch off the circuit breaker. Check the installation and correct any errors. If the wrong dimming principle has been preselected, set the correct dimming principle. If the dimming actuator calibrates itself incorrectly, e.g., with highly inductive mains or long load cables, preselect the correct dimming principle with commissioning.
  • J
    Jason BonillaAug 28, 2025
    What to do if none of the outputs can be operated with Jung Lighting Equipment?
    • G
      grobinsonAug 28, 2025
      If none of the outputs can be operated, it could be that all of the outputs are disabled, in which case you should cancel the disabling. It is also possible that manual mode is active. If the application software is missing or faulty, check the programming and correct it. If the application software has been stopped and the programming LED is flashing, disconnect the device from the bus and mains, then switch it on again after 10 seconds.
  • H
    Hunter MccormickAug 30, 2025
    How to fix LED lamp that is dimly lit when dimmer is switched off (Jung Lighting Equipment)?
    • V
      Victor VegaAug 30, 2025
      If an LED lamp is dimly lit when the dimmer is switched off, the LED lamp may not be optimally suited for this dimmer. Use a compensation module (see accessories). Alternatively, use another type of LED lamp or an LED lamp of another manufacturer.
  • A
    Amber HenrySep 2, 2025
    What to do if connected HV-LED lamps or compact fluorescent lamps in the lowest dimming position are too bright with Jung Lighting Equipment?
    • T
      Taylor TaylorSep 2, 2025
      If connected HV-LED lamps or compact fluorescent lamps in the lowest dimming position are too bright and the dimming range is too small, it could be that the set minimum brightness is too high. Reduce the minimum brightness. Additionally, the HV-LED trailing edge phase control dimming principle may not optimally match the connected lamps. Check operation in the 'HV-LED leading edge phase control' setting and reduce the connected load if necessary and exchange lamps for another type.
  • R
    ronaldlevySep 4, 2025
    How to fix light switches on at maximum brightness and then dims to the target value with Jung Lighting Equipment?
    • L
      Lauren McguireSep 5, 2025
      If the light switches on at maximum brightness and then dims to the target value, the device is likely programmed as a speed controller. You should reprogram the device.
  • P
    pshieldsSep 7, 2025
    How to fix manual control with button field not possible for Jung Lighting Equipment?
    • M
      Michael RileySep 7, 2025
      If manual control with the button field is not possible, it may be because manual control has not been programmed. Program manual control. In other cases, manual control via bus may be disabled.
  • B
    beth73Sep 9, 2025
    Why does Jung Lighting Equipment connected LED lamps or compact fluorescent lamps switch off in the lowest dimming position or flicker?
    • E
      Erin SullivanSep 9, 2025
      If connected LED lamps or compact fluorescent lamps switch off in the lowest dimming position or flicker, the set minimum brightness is likely too low. Increase the minimum brightness.
  • R
    Roberta BennettSep 12, 2025
    What to do when using Jung Lighting Equipment as a speed controller and the motor does not start?
    • J
      James GreenSep 12, 2025
      If, when using the device as a speed controller, the motor does not start, the device may be programmed as a dimmer. Switch off the device immediately. It may also be necessary to reprogram the device.

Jung 3901 REGHE Specifications

General IconGeneral
CategoryLighting Equipment
Operating voltage230 V
Frequency50 Hz
Protection classIP20
MaterialPlastic
MountingDIN rail