Hangzhou Junce Instruments Co., Ltd.
Set negative
over-current
protection
The negative over-current
protection value is set to -20A
The over power protection
value is set to 20W
Set over
temperature
protection
:W25=1,151,150,
:W25=1,211,210,
The over-temperature
protection value is set to 50℃
The over-temperature
protection value is set to 110℃
The battery capacity is set to
200.0Ah
Voltage
calibration
settings
:W29=1,121,120,
:W29=1,81,80,
Set the voltage calibration to
20, and the voltage fine
adjustment is increased.
Set the voltage calibration to
-20, and the voltage fine
adjustment is reduced.
(The value only represents the
fine-tuning factor, the greater
the absolute value of the value,
the greater the amplitude of the
fine-tuning)
Current
calibration
settings
:W30=1,121,120,
:W30=1,81,80,
Set the current calibration to
20, and the current fine
adjustment is increased.
Set the current calibration to
-20, and the current fine
adjustment is reduced.
(The value only represents the
fine-tuning factor, the greater
the absolute value of the value,
the greater the amplitude of the
fine-tuning)
Temperature
calibration
settings
:W31=1,104,103,
:W31=1,99,98,
Set temperature calibration to
3°C, and the temperature
increases by 3°C.
Set temperature calibration to
-2°C, and the temperature is
reduced by 2°C.
Reserved settings
(coming soon)
Reserved settings
(coming soon)
Reserved settings (coming soon)