TECHNICAL
MANUAL
SERIA #R290

Questions and Answers

  • D
    danielsmatthewAug 14, 2025
    Why is the heating effect not good in my Kaisai Air Conditioner?
    • J
      Julia CarlsonAug 15, 2025
      If the heating effect of your Kaisai Air Conditioner isn't satisfactory, check the following: * Compressor frequency: Verify the compressor is running at the correct frequency. * Fan speed: Ensure the fan is running at the appropriate speed. * Exhaust temperature and low pressure: Inspect these to identify potential issues.
  • G
    gillashleyAug 18, 2025
    How to troubleshoot abnormal noise in Kaisai Air Conditioner?
    • C
      Curtis PerezAug 18, 2025
      If your Kaisai Air Conditioner is making an abnormal noise, here's what to check: * Loose screws: Ensure all screws are properly tightened. * Fan: Inspect the fan blade and motor for any issues. * Compressor: Check the compressor for unusual sounds or malfunctions. * Component collisions: Look for any parts that might be colliding with each other.
  • F
    franklinkarenAug 21, 2025
    What to do if my Kaisai KHX-09PY1 Air Conditioner cannot start up?
    • J
      joycebeckerAug 21, 2025
      If your Kaisai Air Conditioner unit won't start, check if the display shows any error messages. Also, inspect the cable connections and reconnect the power cable to see if that resolves the issue.
  • R
    ruth07Aug 25, 2025
    How to fix Kaisai KHX-09PY1 evaporator frosting and defrosting issues?
    • C
      Cynthia BryanAug 26, 2025
      If the evaporator in your Kaisai Air Conditioner has too much frost and isn't defrosting properly, examine the defrosting parameters, compressor frequency, and fan speed. Also, check the exhaust temperature and low pressure.
  • C
    Cassandra WellsAug 28, 2025
    What to do if Kaisai KHX-09PY1 display cannot work?
    • J
      James WilcoxAug 28, 2025
      If the display on your Kaisai Air Conditioner isn't working, first check if the display is locked. Then, inspect the cable connections and reconnect the power cable to ensure a proper connection.
  • M
    Michael SandersAug 31, 2025
    Why does my Kaisai KHX-09PY1 unit trip when powered on?
    • K
      Kevin SmithAug 31, 2025
      If your Kaisai Air Conditioner trips when powered on, it might be due to a short circuit. Check all component connections, relays, and contactors for damage. Try disconnecting electronic components one by one and powering on the unit to isolate the problem.
  • J
    Jamie GreenSep 3, 2025
    How to troubleshoot a Kaisai Air Conditioner display with no power?
    • V
      vjohnstonSep 3, 2025
      If the display on your Kaisai Air Conditioner isn't getting power, check the display cable and the power cable. Also, verify that the 3-phase power cable is connected with the correct phase sequence.
  • K
    Keith BerrySep 7, 2025
    Why does my Kaisai KHX-09PY1 shut off before reaching the target temperature?
    • R
      rodriguezandreaSep 7, 2025
      If your Kaisai Air Conditioner shuts off before reaching the target temperature, check the parameters related to the temperature limit, considering the ambient temperature.
  • S
    Sonia SullivanSep 10, 2025
    What does E04 error mean on my Kaisai KHX-09PY1 Air Conditioner?
    • J
      julielopezSep 10, 2025
      To address the E04 Electric heater over heat Protection error in your Kaisai Air Conditioner: 1. Check if the Electrical heating Overheat protector is open. 2. Inspect the Electrical heater.

Summary

Preface

Safety Instructions

Mark and Icon Notes

Explains warning marks and operational icons for safety.

Critical Safety Warnings

Details operational, maintenance, and repair safety warnings.

Installation & Operation Attention

Highlights crucial attention points for installation and operation safety.

Features

Key Unit Features

Lists core features like advanced control, appearance, installation, and working range.

Unit Dimensions

Model Dimensions

Provides dimensional drawings and specifications for KHX-09PY1, KHX-14PY3, KHX-16PY3.

Installation Types

Traditional Installation

Connecting heat pump with buffer, storage tanks, and external water pumps.

Hydronic Module Installation

Connecting heat pump to Hydronic box with integrated components.

Multi-functions Tank Installation

Connecting heat pump to a comprehensive multi-functions tank system.

Handling, Installation & Operation

Unit Handling Features

Key unit features such as refrigerant type, operating environment.

Installation Guidelines

Covers choosing the unit, installation methods, and suitable locations.

Water & Power Connection

Procedures for connecting water loops and power supply systems.

Trial Running Procedures

Steps for unit inspection and trial running before full operation.

Maintenance

Daily Maintenance Precautions

Preparations and checks for daily or initial unit startup.

Periodic & Inspection Maintenance

Maintenance tasks for heat exchangers, wiring, and safety checks.

Product Cleaning & Checks

Guidelines for cleaning the unit and checking key components like evaporator and fan.

Parameters

Operation Range & Performance Curves

KHX-09 PY1 Performance

Performance data and curves for model KHX-09PY1.

KHX-14 PY3 Performance

Performance data and curves for model KHX-14PY3.

Explosion Views

KHX-09 PY1 Component Breakdown

Illustrated exploded views of the unit and its electric box.

KHX-14 PY3 Component Breakdown

Illustrated exploded views of the unit and its electric box.

KHX-16 PY3 Component Breakdown

Illustrated exploded views of the unit and its electric box.

Wiring Diagrams

KHX-09 PY1 Wiring Diagram

Detailed electrical wiring diagram for the KHX-09PY1 model.

KHX-14 PY3 Wiring Diagram

Detailed electrical wiring diagram for the KHX-14PY3 model.

KHX-16 PY3 Wiring Diagram

Detailed electrical wiring diagram for the KHX-16PY3 model.

Display Operation Guide

Main Interface & Controls

Overview of the main interface and basic display functions.

Mode & Temperature Settings

How to switch modes and set target temperatures.

System Settings

Covers setting interface, time, timers, and brightness.

Status & Fault Display

How to check unit status and view/manage fault records.

Electrical Parameters

Troubleshooting

Failure Handling Guide

Lists common issues, causes, components, and solutions.

Error Code Instructions

Explains specific error codes and their resolution steps.

MODBUS RTU Protocol

Communication Protocol Format

Details transmission format, packet structure, and data types.

Register Mapping & Content

Maps MODBUS addresses to device parameters and their content.

Kaisai KHX-09PY1 Specifications

General IconGeneral
TypeSplit
Cooling Capacity2.6 kW
Heating Capacity2.8 kW
Energy Efficiency Ratio (EER)3.21
Power Supply220-240V, 50Hz
RefrigerantR32
SEER6.1
SCOP4.0
Noise Level (Outdoor)52 dB(A)