kansai TSK-18 - Blower Warning

Default Icon
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
*1
8-3
B
lower warnin
g
All the operation of hot-air generator is stopped when the blower became overload, overcurrent, and lock.
At the time of the blower warning
BLOWER WARN. lamp (Red) is lighted and "InV" is
flickered to HOT-AIR TEMP., "ALM" to SETTING
TEMP.
Main cause
Wear of the bearing
Abnormal voltage (Voltage more than the rating)
Piping of many pressure loss
Opening the use of an extremely narrow nozzle
Return method
Abnormality is displayed to the inverter panel *
1
that was established inside. Please turn off the
breaker of this machine after the display contents
are confirmed. And, please communicate the
dis
p
la
y
contents.
The position of the inverter panel differs by the machine type.
TSK-18 Back side of the control panel service terminal
TSK-23
33 The inside of the back panel
TSK-42
52 The inside of the control panel (Please open the control panel and please confirm.)
TSK-52HT The inside of the back panel
TSK-56 The inside of the control panel (Please open the control panel and please confirm.)
TSK-62
72 The inside of the back panel
TSK-82 The inside of the back panel
TSK-92
102 The inside of the back panel
TSK-122
132 The inside of the grid window of he control panel
Attention : Please block the source power supply (factory power supply) without fail when the
wiring is confirmed and readjusted at the time of abnormal.