At the time of the burnout of the external sensor
Hot-air generator is stopped when the external sensor became the burnout of snapping of a wire etc. in the
case that the temp. of the place that parted is controlled by using the external sensor of the option.
"---" is flickered to HOT-AIR TEMP., "TC0" to
SETTING TEMP. (EXT. SENSOR lamp is being
lighted.)
《
Main cause
》
Snapping of a wire of the external sensor
Snapping of a wire of the external sensor
compensating wire
Miss of the inlet sensor wiring terminal
《
Return method
》
Please disarm by pushing STOP switch after the
confirmation of the external sensor.
Reverse connection by each sensor or detection of minus temp.
Hot-air generator is stopped at the time of the reverse connection of each temp. sensor (External sensor is
included) or perception of -15
゚
C. (Only inside temp. sensor is -10
゚
C.)
"---" is flickered to HOT-AIR TEMP, display of each
sensor to SETTING TEMP
External sensor
: Tc0 Outlet sensor : TcA
Overheat sensor
: TcM Inlet sensor : Tcc
Inside temp. sensor
: Tcb
《
Main cause
》
Reverse connection of the external sensor
Reverse connection by the wiring readjustment of
each sensor
Atmosphere temp. or suction temp. of minus
《
Return method
》
lease disarm by pushing STOP switch after the
confirmation of the external sensor or the
improvement of the minus condition. Please
order the repair about except for reverse
connection o
the external sensor.
Attention : Please block the source power supply (factory power supply) without fail when the
wiring is confirmed and readjusted at the time of abnormal.
-14-