EasyManua.ls Logo

Kanto CM600 - Mount Plate Assembly for Concrete Ceilings

Kanto CM600
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
x4
Concrete
Anchor (P)
Ancrages
de béton (P)
Anclajes para
concreto (P)
3/8”
(10mm)
2¾” (70mm)
9
O
3.1
3.2
3.3
3B. Mount plate assembly (concrete) / Montage de la plaque
(béton) / Monte el conjunto de la placa (concreto)
13mm
CAUTION
Make sure the concrete is at least 4” thick. Make sure the anchor is seated completely ush with the concrete surface even if there is another layer of
material, such as drywall. If drywall is over 5/8” thick, custom lag bolts must be used. Concrete must be a minimum of 2000psi in density.
ATTENTION:
Assurez-vous que le béton est d’au moins 4” d’épaisseur. Assurez-vous que l’ancre est comptement ras avec la surface du béton, même sil y a une autre couche
de matérial, comme le placoplâtre. Si le placoptre est supérieure à 5/8” d’épaisseur, des tire-fonds personnalisés doivent être utilis. La densité du béton doit être
supérieure à 2000 psi.
PRECAUCIÓN:
Asegúrese de que el hormigón de al menos 4” de espesor. Asegúrese de que el ancla esté asentado completamente y enrasada con la supercie de hormin,
inclusive si hay otra capa de material, tales como paneles de yeso. Si la tablaroca tiene un grosor de más de 5/8” se deberan usar pernos personalizados. El
concreto debe ser de un mínimo de 2000 psi de densidad.