EasyManua.ls Logo

Kärcher SBP 2200 - User Manual

Kärcher SBP 2200
68 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Register and win!
www.kaercher.com
SBP 2200
SBP 3800
59627490 10/2012
Deutsch 5
English 12
Français 19
Italiano 26
Nederlands 33
Español 40
Português 47
Ελληνικά 54
Українська 61

Questions and Answers

  • S
    sandra66Jul 25, 2025
    What to do if Kärcher Power Pump does not run?
    • A
      Angela MillerJul 25, 2025
      If your Kärcher Power Pump stops running or suddenly comes to a standstill, several factors could be at play. First, check the fuses and electrical connections to ensure the power supply hasn't been interrupted. The thermal protection switch in the motor might have switched off the pump due to overheating; if this is the case, pull out the mains plug, let the pump cool down, clean the suction area, and prevent dry running. Also, dirt particles may have jammed the suction area, so pull out the mains plug and clean it. Finally, the pump operation might have been stopped by a sensor, so verify the level sensor's position.
  • C
    Christopher MataAug 1, 2025
    How to fix Kärcher Power Pump that runs but does not pump water?
    • T
      Tonya NelsonAug 1, 2025
      If your Kärcher Power Pump runs but doesn't transport water, it could be due to several reasons. Air might be trapped in the pump; try plugging in and pulling out the mains plug a few times until the fluid gets sucked in. Alternatively, the suction area might be blocked, so pull out the mains plug and clean it. If operating in manual mode, ensure the water level is above the minimum; immerse the pump deeper if possible or follow the instructions for automatic operation. A blocked pressure hose could also be the culprit; pull out the mains plug and clean the pressure hose. Finally, check that the locking tap is open (arrow vertical).
  • R
    Richard FernandezAug 8, 2025
    Why is the pumping capacity too low on my Kärcher Power Pump?
    • A
      Andrew ToddAug 9, 2025
      If your Kärcher Power Pump's pumping capacity is too low, remember that the pumping capacity depends on the flow height, hose diameter, and hose length. Keep the flow height within the maximum specified in the technical data. If necessary, select a different hose diameter or hose length to improve performance.
  • S
    Sandra PierceAug 17, 2025
    What to do if Kärcher Power Pump pumping capacity is reducing?
    • S
      Stephen MorganAug 17, 2025
      If the pumping capacity of your Kärcher Power Pump is reducing, it might be because the suction area is blocked. To resolve this, pull out the mains plug and clean the suction area.

Summary

General Information and Proper Use

General Information

Read and comply with original instructions before initial operation for later use or subsequent owners.

Proper Use

Appliance designed for private households, not commercial use; intended for rain water or immersion pump use.

Environmental Protection

Packaging and old appliances are recyclable. Dispose of old appliances properly.

Warranty Information

Warranty terms are country-specific; contact dealer for repairs due to faulty material or manufacturing.

Safety and Stability

Symbols in the Operating Instructions

Explanation of danger, warning, and caution symbols indicating potential hazards.

Safety Instructions

Essential safety guidelines including electrical safety, cord handling, and qualified repairs.

Prerequisites for Appliance Stability

Ensuring appliance stability on an even surface before performing any work.

Pump Operation Guide

Description of the Appliance

List of components and parts of the pump system.

Preparing the Drum Pump Operation

Steps to connect hose and prepare the pump for use with a drum.

Different Uses of the Level Switch

Instructions for setting the level switch for automatic or manual operation modes.

Preparing the Immersion Pump Operation

Steps to connect hose and prepare the pump for immersion use.

Automatic Operation

How the level switch controls pumping operations automatically based on fluid levels.

Manual Operation

How to operate the pump continuously in manual mode, with dry run warning.

Comfort Operation (SBP 3800)

Specific comfort mode operation for SBP 3800, independent of water level.

Finish Operation

Procedure for stopping the pump and disconnecting it from the power source.

Maintenance, Transport, and Storage

Maintenance and Care

Instructions for cleaning the pump, filter basket, and foam filter.

Transport

Guidelines for safely transporting the appliance by hand or in vehicles.

Storage

Recommendations for storing the appliance, including in a frost-free area.

Special Accessories

Information on available special accessories, such as suction hoses.

Troubleshooting and Specifications

Troubleshooting

Common faults, their causes, and remedies for pump operation issues.

Specifications

Technical data for SBP 2200 and SBP 3800, including voltage, output, and dimensions.

Kärcher SBP 2200 Specifications

General IconGeneral
Weight4.2 kg
Dimensions (L x W x H)215 x 224 x 303 mm
Power consumption2200 W
Max. immersion depth7 m
Cable length10 m
Voltage230 V
Frequency50 Hz
Protection ClassIPX8