Camera Link Range Extender over Fiber User Manual
26
Symbol
Parameter
Test condition (note 1)
MIN
MAX
Units
V
IH
Input High Voltage
V
OUT
≥ V
OH (min)
or
V
OUT
≤ V
OL (max)
0
5
V
V
IL
Input Low Voltage
-5
V
I
IN
Input Current
V
IN
= 0 V or V
IN
= V
DD
1
µA
Note: Vdd = 5V, unless specified otherwise
Table 15 : KY-EXT-CL RS232 input specifications
Symbol
Parameter
Test condition
MIN
MAX
Units
V
OH
Output High Voltage
2.7
V
V
OL
Output Low Voltage
0.4
V
Note: Vdd = 5V, unless specified otherwise
Table 16 : KY-EXT-CL RS232 output specifications