Do you have a question about the Kaz Vicks Warm Steam and is the answer not in the manual?
Details the safety mechanism requiring cord unplugging and notes on nightlight operation after connection.
Requires receipt as proof of purchase and explains LOT number usage for production date identification.
Warns against attempting self-repairs, as it voids warranty and may cause damage or injury.
Covers operation, supervision, handling, and electrical safety for the vaporizer.
Highlights key warnings such as not heating on stoves or using a damaged cord.
Emphasizes unplugging the unit, ensuring the cable is fully unravelled, and avoiding use with wet hands.
The Vicks Warm Steam Vapourizer is designed to provide warm steam for humidification, intended for indoor use. It operates by heating water to produce a gentle flow of steam, which helps to increase humidity in a room. The device is equipped with a safety mechanism that requires the cord to be unplugged for a short period before reconnection if the heating unit is removed from the water reservoir during operation, preventing immediate restart. A nightlight is integrated into the unit, illuminating only when the vapourizer is actively operating.
To begin using the vapourizer, ensure the cord is fully unravelled and free of knots. The device must be placed on a firm, even, non-metallic, and waterproof surface, at least 1.2 meters (4 feet) from the bedside, preferably on the floor, to prevent accidental falls or being pulled down. It is crucial to protect the floor, rug, or furniture by placing the vapourizer on a non-metallic, heat-resistant surface. The steam flow should not be directed directly at recipients, walls, or furniture.
Before filling, the heating unit must be removed. This is done by lifting the rear cap, rotating it counter-clockwise until the slanted portions of the two locking tabs are cleared, and then lifting the unit directly upwards. The container should be filled with tap water up to the MAX water level marked on the reservoir, taking care not to overfill. Once filled, the heating unit is replaced by aligning its two locking tabs with the slots in the water reservoir, ensuring it engages properly, and then rotating the head clockwise to secure it in place.
The vapourizer is activated by plugging it into a single-phase AC supply matching the voltage on the rating plate. It is important to note that the vapourizer will not start if it has not been disconnected for at least one minute prior to plugging it in. The nightlight will illuminate upon connection, indicating that the heating unit is functioning. A gentle flow of steam will begin within a few minutes. The device should not be lifted or moved while in use.
For enhanced relief, the vapourizer includes a medicine cup located on the cap of the steam outlet vents. This cup is designed for use with KAZ Inhalant or Vicks VapoSteam, or other steam inhalants or medicine oils available in drugstores and pharmacies. It is critical to only place these products in the medicine cup and never directly into the water tank, as doing so will damage the unit and void the guarantee. These inhalants are typically designed for one vapourizer cycle (12-14 hours). After the vapourizer shuts off, any residue in the medicine cup should be emptied and cleaned with a soft tissue before refilling.
The vapourizer is designed to shut off automatically when the water level reaches a minimum level (approximately 20 mm from the bottom of the container). If excessive humidity leads to condensation on walls in closed or small rooms, it is recommended to periodically check for proper ventilation, or to turn the power switch to the lower setting and open the door to the room. The hot steam should not be touched, as it can cause burns.
Regular maintenance is essential for the proper operation and longevity of the Vicks Warm Steam Vapourizer.
After each use, any unused water should be emptied from the container. The container should then be rinsed thoroughly, drained, and wiped with a dry, clean cloth.
Similar to daily maintenance, unused water should be emptied, and the container rinsed, drained, and wiped dry. Additionally, the heating unit requires more thorough cleaning. This involves soaking the heating unit in 8 cm (3 inches) of white vinegar for 10 minutes. After soaking, a butter knife can be used to gently remove any mineral deposits from the metal heater surface. Access to the heater surface is gained by lifting the hinged cover on the bottom of the unit.
The heater surface should be cleaned after every 150 hours of operation. This is done by opening the hinged cover on the bottom of the heating unit and using a butter knife to gently remove any mineral deposits. In areas with hard water, more frequent cleaning may be necessary. For proper operation, it is crucial that the hinged cover is shut and in the correct position after cleaning.
When the vapourizer will not be used for an extended period, such as at the end of a season, or for several days, the weekly maintenance procedure should be followed. All parts must be thoroughly dried, and the unit should be stored in a cool, dry location. It is important never to store the unit with water inside.
Before any cleaning or maintenance, always disconnect the plug from the electrical outlet. Remove the heating unit and allow all water to drain back into the container. Do not attempt to disassemble the heating unit, as this could damage the vapourizer, cause personal injury, and void the warranty.
If the nightlight does not illuminate after the cord is connected, disconnect the plug and wait at least one minute before reconnecting. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid a hazard. The appliance should not be used if it is damaged, shows signs of damage, or is not functioning properly; in such cases, the power plug must be disconnected from the power socket. If moisture is noticed on the inside of windows, the humidifier should be turned OFF. For accurate humidity readings, a hygrometer is recommended. The device should never be operated with wet hands, and the cord should always be pulled by the plug, not the cord itself.
| Type | Warm Steam Vaporizer |
|---|---|
| Medication Cup | Yes |
| Auto Shutoff | Yes |
| Output | Warm, moist vapor |
| Features | Automatic Shut-Off, Medicine Cup, Night Light |
Loading...