Models 1000U-48, 1500U-48, 2000U-48
DBL MX-U Series UPS
Manual
UNLESS SPECIFICALLY AGREED TO IN WRITING, SELLER
(A) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER
INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION;
(B) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES, COSTS OR EXPENSES, WHETHER SPECIAL,
DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE
USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER’S RISK; AND
(C) REMINDS YOU THAT IF THIS MANUAL IS IN ANY LANGUAGE OTHER THAN ENGLISH, ALTHOUGH STEPS HAVE BEEN TAKEN TO
MAINTAIN THE ACCURACY OF THE TRANSLATION, THE ACCURACY CANNOT BE GUARANTEED. APPROVED CONTENT IS
CONTAINED WITH THE ENGLISH LANGUAGE.
(D) INFORMS YOU THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE.
(E) RESERVES ALL RIGHTS.
DBL MX-U Series UPS Outdoors 1000-2000W 120V Manual English 20180312
- This manual is for qualified
personnel only

Questions and Answers

  • Z
    Zachary BeckerAug 4, 2025
    What to do if Keatec Energy DBL MX-U inverter is out of order?
    • K
      Kevin RuizAug 4, 2025
      If the inverter is out of order, check and verify the AC input connections. Also, check and verify the Bypass connections Load (RED) Line (BLACK) and reconnect all AC connections. Make sure that the load does not exceed the rated output of the UPS and that the input voltage is within the range of
  • S
    Shaun EdwardsAug 11, 2025
    What to do if Keatec Energy DBL MX-U UPS shows inverter short circuit?
    • S
      Samantha ReynoldsAug 12, 2025
      If the UPS indicates an inverter short circuit, check and verify the AC connections, ensuring that the Red wire is connected to the Load and the Black wire to the Line. Also, check the load for any short circuits. If the UPS is set to not retry, it will lock directly and show an error code and alarm. Clear the short and restart the UPS.
  • K
    Kimberly BakerAug 18, 2025
    What to do if Keatec Energy UPS battery is weak or dead?
    • D
      Donald JordanAug 18, 2025
      If the UPS indicates a weak or dead battery, check and verify the battery quantity, ensuring it does not exceed the maximum of 6 x 55AH without external ABM. Consider the age of the batteries and whether there has been a recent power failure. If the battery voltage measured during self-test is below 8nV (or 4mS) or 10.4nV (128ms), or if the battery voltage drops to 8nV suddenly, or if the battery voltage is lower than 12.5nV, the UPS will cease the self-test and show an error. For faster recharge, consider installing ABM.
  • K
    Kevin Webb MDAug 26, 2025
    What to do if Keatec Energy DBL MX-U UPS shows DC BUSS abnormal high-voltage-level?
    • D
      Donna HollowayAug 27, 2025
      If the UPS shows a DC BUSS abnormal high-voltage-level, remove all DC and AC connections. Connect the batteries, perform a DC Cold-Start, and when the UPS is operating, apply AC by connecting the AC harness.

Summary

Important Safety Instructions

UPS Functions and Descriptions

Front Panel Views

Identifies and explains the components on the UPS front panel.

Control Panel Overview

Details the functions of the UPS control panel buttons and indicators.

LCD Display Description

Explains the meaning of various symbols and icons on the control panel.

Timer Display Description

Describes the secondary timer display and its functions.

Hot Swap Bypass Switch

Bypass Switch Operation and AUTO Position

Bypass Switch Operation

Details the operation of the bypass switch and its LED indicators.

AUTO Position (UPS Operating)

Describes the UPS operation when the switch is in AUTO position.

DBL MX UPS Installation

AC Line Mode Startup

LCD Control Panel and Parameter Viewing

Cold Start (DC start) Using the Batteries Only

UPS Latch Alarm Conditions

Procedures to Release UPS from Locked Status

Outlines the steps to clear a latched alarm and restore UPS operation.

Changing The MX-U Parameters

UPS Power Off and Self-Test Operations

Self-Test (AC mode only)

Test for checking the state of the battery pack in AC mode.

Manual ECO;Inverter Mode

Manually changing UPS mode to ECO or Inverter without shutting down load.

UPS Relay Output Card

Emergency Power Off; Without Voltage

Explains the EPO function for emergency power shutdown.

Trouble Shooting

Reference Error Codes

Lists common error codes, their results, occurrences, status, and actions.

DBL MX-U Specifications

INPUT Specifications

Details voltage, frequency, phase, and power factor for UPS input.

OUTPUT Specifications

Details voltage regulation, frequency, waveform, and outlets for UPS output.

BATTERY Specifications

Details DC Buss Voltage, Charger Amps, and battery charging parameters.

UPS Maintenance

Battery Testing and Maintenance

Instructions for testing and maintaining UPS batteries under various conditions.

Keatec Energy DBL MX-U Series Specifications

General IconGeneral
ModelDBL MX-U Series
CategoryUPS
ManufacturerKeatec Energy
TopologyDouble Conversion Online
Waveform TypePure Sine Wave
Transfer Time0 ms
DisplayLCD
Output Power Capacity1 kVA - 10 kVA
Input Voltage230V
Input Frequency50/60Hz
Output Voltage230V
Output Frequency50/60Hz
Battery TypeSealed Lead-Acid (SLA)
Communication InterfaceRS232, USB
Protection FeaturesOverload, Short Circuit
Operating Temperature0°C to 40°C
DimensionsVaries by model
WeightVaries by model
WaveformPure Sine Wave