UPS-D Series
Unintrerruptible Power
Supply
DOC NBR:
TEC-876
APRVD:
JMC 9/24/14
Equipment Operation
PAGE
1 OF 3
1.0
Scope
This instruction installation, operation and troubleshooting of the Multistar D-series
uninterruptible power supply (UPS). covers replacement of an infrared lamp emitter
in an IR furnace chamber Applies to most RTC, GBT and LCI infrared furnaces.
2.0
Introduction
UPS-D series can instantly switch you computer to emergency backup power and
allows you to respond to brief power outages reducing possibility of data loss or
downtime. It continuously conditions the power coming into your computer and acts
as a power supply. This state-of-the-art UPS is specificatlly designed for PC users
and is also suitable for computer periherals. It is equipped with an LCD display for
the working status. The UPS has a microprocessor controller that renders the product
an intelligent UPS capable of self-protection and fault diagnosis. The built-in AVR
functions automatically to maintain a stable voltage supply as the supply power
varies. High-performance surge supression helps to protect the furnace computer
from electrical noise and damaging power surges.
3.0
Performance
Uninterruptible Power. Protects data by supplying batery backup when power fails.
Microprocessor Control. Provides diagnostics.
LCI Display and Audible Alarms. Actively informs when unit is on battry, if the battery is low, or if there is an
overload condition.
Battery. Sealed lead-acid maintenance-free battery.
Automatic Detection. When the UPS is powered ON, it immediately performs an inspection of the battery capacity.
Automatic Voltage Regulation. Corrects over and under voltage conditons without draining the battery. This
preserves battery resources and ensures optimum runtime during complete loss of power.
Surge Protection. Shields hardware from damage from line power surges.
Automatic Charge. The UPS charges its battery whenever it is connected to facilty power.
4.0
Installation
Location. Must be in a protected area with adequate airflow and free of excessive dust. Do not operate the
UPS where the temperature and humidity is outside the specified limits.
Charge battery. The battery in the UPS will lose some charge when the unit is offline, even when there is
no drain on the discharge side. The UPS will completely recharge after 8 hours of normal operation. Do
not expect full battery run time during an extended recharge.
Figure 1-1 Multistar UPS-650D

Questions and Answers:

Kebo UPS-650D Specifications

General IconGeneral
BrandKebo
ModelUPS-650D
CategoryUPS
LanguageEnglish

Summary

UPS-D Series Performance Features

Uninterruptible Power

Provides battery backup when power fails to protect data.

Microprocessor Control

Enables diagnostics for intelligent UPS operation.

Automatic Detection and Regulation

Inspects battery capacity on power-on and regulates voltage.

Surge Protection

Shields hardware from damage caused by line power surges.

Installation Guidelines

UPS-D Series LCD Display Information

UPS-D Series Operation

Low Battery Alarm

Rapid beeping when battery energy is low, before shutdown.

Overload Alarm

Continuous alarm for 30 seconds when overloaded; disconnect loads.

Battery Alarms

Troubleshooting UPS Issues

UPS Not On / LCI Not Lit

Check POWER button, PCB failure, or call for service.

UPS Stays at Battery Mode

Check power cord, AC fuse, voltage, or PCB failure.

Short Runtime / Premature Low Battery Warning

Recharge battery for 8 hours; replace if warning persists.