Solar Hot Water Systems
Installation Manual

Questions and Answers

  • T
    Terrance WareSep 5, 2025
    What to do if my Kelvinator Heat Pump is not running?
    • N
      Nichole TaylorSep 5, 2025
      The temperature inside the tank could be above the set point, causing the unit to shut down. When the temperature drops below the set point, the unit will start automatically and begin heating the water again. Also, under colder conditions, the heat pump may shut down to enter defrost mode. If the heat pump is wired to an off-peak tariff, it will only run when this supply is available. Finally, the heat pump requires 3 minutes of uninterrupted power supply to operate as part of its protection.
  • S
    Sarah Jordan MDDec 1, 2025
    Why Kelvinator KCT45036A water is cold?
    • A
      April FieldsDec 1, 2025
      If a large amount of hot water has been used, or the system has been newly commissioned or drained, it may take some time for the water temperature inside the tank to reach a normal level (electric boosted only). Also, check that power is available to the solar controller and the green LED marked 'SOLAR' is lit. Check that power is turned on to the storage tank element. If the tank element is installed on an off- peak power supply, power may only be available at certain times of the day (electric boosted). Check that there is power and gas available to the gas continuous flow water heater (gas boosted only). Check there is enough flow coming from the fixture to start the gas continuous flow water heater (gas boosted only). Check for cross plumbing between the cold water and hot water lines...
  • L
    Lisa ThomasSep 18, 2025
    What to do if the fan is not running on my Kelvinator Heat Pump?
    • B
      Brittany BurnsSep 18, 2025
      If the fan stops indefinitely while the rest of the heat pump is operating, please call a service technician.
  • D
    Diane BarkerSep 16, 2025
    Why is there a small amount of water leaking from underneath my Kelvinator Heat Pump?
    • T
      Theodore MyersSep 16, 2025
      Water may collect in the bottom tray of the heat pump due to rain or condensation as part of the normal operation. There is a drain hole on the bottom tray that allows water to run out, and a drainage pipe may be connected to this hole. If an excessive amount of water is coming from this hole/drainage pipe or anywhere else on the heat pump, please call a service technician.
  • M
    Michael WashingtonSep 14, 2025
    What to do if the boost element in my Kelvinator Heat Pump storage tank is not operating?
    • B
      Bonnie AvilaSep 14, 2025
      Power must be available to the heat pump for it to change to electric heating manual mode. Check that the circuit breaker is switched on.
  • M
    Michael HansenSep 12, 2025
    How to troubleshoot a cold water tank with a non-running Kelvinator Heat Pump?
    • K
      Kelsey MorrisonSep 12, 2025
      Check that power is available at the switchboard supplying the heat pump and that its circuit breaker is on or that the fuse is in. If there is an isolator switch for the heat pump installed, check that this is not switched off. If the circuit breaker is tripped or the fuse is blown, call a service technician.
  • L
    Larry ThorntonSep 12, 2025
    What to do if there is low water pressure from my Kelvinator Heat Pump hot taps?
    • T
      taylorannaSep 12, 2025
      Check that all isolation valves in the water system are fully opened, including the isolation valve at the mains water meter and the inlet to the hot water system. Also, ensure that all filters in the hot water system are clean and free from blockages, including any filters on individual taps or fixtures and the tempering valve.
  • S
    Sheila MooreSep 9, 2025
    What to do if water is discharging from the pressure relief valve on my Kelvinator Heat Pump storage tank?
    • B
      Bryan JonesSep 9, 2025
      A small amount of water may discharge regularly from the relief valve to compensate for water expansion upon heating. However, if a large volume of water is being discharged with steam, turn off power to the heat pump and call a service technician. If there is a small but continuous leak, operate the lever on the relief valve a couple of times to see if the leak stops; if the leak continues, call a service technician.
  • J
    Judith JenningsSep 7, 2025
    What to do if my Kelvinator Heat Pump has power but isn't running and the water is cold?
    • J
      Johnny MyersSep 7, 2025
      The Kelvinator Heat Pump may have shut down due to a fault. Turn the power off to the heat pump for a few seconds, then power it back on. This may reset the heat pump from a protection mode, potentially caused by a power surge. If this occurs again, it may indicate a fault condition, and you should call a service technician.
  • C
    Christopher WilliamsAug 21, 2025
    Why does it take so long to get hot water from my Kelvinator KCT45036A Water System?
    • G
      gmooreAug 21, 2025
      The time it takes for hot water to reach your fixtures depends on the distance and size of the pipes, as well as the water flow rate. Longer distances, larger pipe diameters, or slower flow rates will increase the time it takes. This is normal and not a defect.