MODULE LINE
Operating Instructions 77 500..B..
Spring-applied single-disc brake module
Types: 77 50013B16 77 50019B15
77 50024B15 77 50029B15

Questions and Answers

  • C
    Christina WarnerAug 13, 2025
    Why Kendrion 77 50024B15 brake torque too low?
    • A
      Amanda WallAug 13, 2025
      If the Kendrion Control Unit brake torque is too low, consider these potential causes: 1. The air gap may be too large. Check the air gap and replace the friction disc if necessary. 2. The friction surfaces could be oily or greasy. Replace the friction disc. 3. The compression spring might be broken. Install a new brake module.
  • T
    Timothy BaileyAug 17, 2025
    Why Kendrion Control Unit has delayed brake release?
    • D
      Diana MontgomeryAug 17, 2025
      If the Kendrion Control Unit experiences delayed brake release, it could be due to: * An air gap that is too large. Inspect the air gap and replace the friction disc if necessary. * A voltage applied to the field coil that is too low. Check the field coil supply voltage and correct any identified faults.
  • J
    jenniferhartAug 22, 2025
    What to do if Kendrion 77 50024B15 brake engagement failure?
    • L
      Linda VargasAug 23, 2025
      If the Kendrion Control Unit brake engagement fails, it might be because: * The voltage applied to the field coil in an unpowered condition is too high (residual voltage). Check for residual voltage applied to the field coil and correct any faults found. * The armature plate is mechanically blocked. Eliminate any mechanical obstructions, and if necessary, install a new brake.
  • C
    Colton FigueroaAug 27, 2025
    Why Kendrion 77 50024B15 has delayed brake engagement?
    • L
      lesliemillerAug 27, 2025
      If the Kendrion Control Unit experiences delayed brake engagement, it is possible that the voltage applied to the field coil is too high. Check the field coil supply voltage and correct any faults that are found.
  • T
    thomasthompsonSep 1, 2025
    How to fix Kendrion 77 50024B15 microswitch failure?
    • E
      Eric ChavezSep 2, 2025
      If the Kendrion Control Unit microswitch fails, it could be due to: * A damaged microswitch. Replace it with a new one. * An adjustment error of the microswitch switching point. Readjust the microswitch switching point.
  • D
    Daniel ThomasNov 6, 2025
    What to do if Kendrion 77 50024B15 Control Unit brake release failure?
    • C
      Cynthia ChanNov 6, 2025
      If the Kendrion Control Unit brake release fails, several factors could be responsible: * The air gap might be too large, in which case you should check it and replace the friction disc if needed. * There might be no voltage applied to the brake, so you should check the electrical connection and fix any issues. * The voltage applied to the field coil may be too low, so check the field coil supply voltage and correct any faults. * The armature plate might be mechanically blocked, requiring you to remove any obstructions. If needed, install a new brake. * The rectifier could be damaged; inspect and replace it if necessary. * A damaged field coil could be the issue; check its resistance and replace the brake if required. * Lastly, the friction disc might be thermally overloaded...

Summary

Safety

Safety and Warning Symbols

Explains safety symbols and provides general safety information for safe operation.

Installation Safety

Covers safety aspects during the installation of the brake module, including electrical and heat considerations.

Start-up Safety

Details critical checks and conditions to ensure safe start-up of the brake module.

Operation Safety

Provides safety guidelines for operating the brake module to prevent hazards.

Radio Interference Suppression

Product Description

Operating Principle

Explains the fundamental operating mechanism of the spring-applied single-disc brake module.

Installation

Mechanical Installation

Provides general instructions and considerations for the mechanical installation of the brake module.

Brake Shaft Installation

Step-by-step guide for installing the brake shaft onto the motor shaft.

Mechanical Installation

Mounting Brake Module to Motor

Detailed procedure for securely mounting the brake module onto the motor flange.

Electrical Connection and Operation

AC Power Supply

Electrical Connection with Microswitch

Set-up and Start-up

M4 Transmissible Torque Adjustments

Maintenance

Checks and Service Procedures

Microswitch Adjustment

Brake Shaft Removal

Troubleshooting

Technical Specifications

Kendrion 77 50024B15 Specifications

General IconGeneral
BrandKendrion
Model77 50024B15
CategoryControl Unit
LanguageEnglish