EasyManua.ls Logo

Kenmore 27" - Venting Kits

Kenmore 27"
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ventin 9 Kits
For more information, call 1-800-901-2042, or visit us at
www.applianceaccessories.com, in Canada, call
1-800-807-6777 or visit us at www.whirlpoolparts.ca.
Part Number Descriptions
8171587RP 0-5" Metal vent periscope
4396037RP 0"-18" Metal vent periscope
4396011RP 18" - 29" Metal vent periscope
4396014 29" - 50" Metal vent periscope
4392892 In-Wall metal DuraVent TM Periscope
279818 4-way vent kit - white
W10186596 4-way vent kit - universal grey
4396028 Sure Connect TM venting kit
(over-the-top installation)
4396009RP 5' Universal connect vent, flexible dryer venting
4396010RP 6' SecureConnect TM vent, flexible dryer venting
4396013RB Dryer vent installer's kit
4396033RP 5' flexible dryer venting with clamps
4396727RP 8' flexible dryer venting with clamps
4396004 Dryer offset elbow
4396005 Wall offset elbow
4396006RW DuraSafe TM close elbow
4396007RW Through-the-wall vent cap
4396008RP 4" steel dryer venting clamps - 2 pack
8212662 Flush mounting Iouvered vent hood 4"
Special provisions for mobile home installations:
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
Determine vent path:
[] Select route that will provide straightest and most direct
path outdoors.
[] Plan installation to use fewest number of elbows and turns.
[] When using elbows or making turns, allow as much room
as possible.
[] Bend vent gradually to avoid kinking.
[] Use as few 90° turns as possible.
Determine vent length and elbows needed for best
drying performance:
[] Use following Vent system chart to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified
in Vent system chart. Exhaust systems longer than those
specified will:
[] Shorten life of dryer.
[] Reduce performance, resulting in longer drying times
and increased energy usage.
The Vent system chart provides venting requirements that will
help achieve best drying performance.
Vent System Chart
Number of Type Box/Iouvered Angled
90 ° turns of vent hoods hoods
or elbows
0 Rigid metal 64 ft. (20 m) 58 ft. (17.7 m)
1 Rigid metal 54 ft. (16.5 m) 48 ft. (14.6 m)
2 Rigid metal 44 ft. (13.4 m) 38 ft. (11.6 m)
3 Rigid metal 35 ft. (10.7 m) 29 ft. (8.8 m)
4 Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m)
NOTE: Side and bottom exhaust installations have a 90° turn
inside the dryer. To determine maximum exhaust length, add
one 90° turn to the chart.
15