EasyManuals Logo

Kenmore 796.9139 User Manual

Kenmore 796.9139
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
22
RESTRICTED OR BLOCKED AIRFLOW
Check the duct condition.
If the CHECK VENT LED is blinking, check the exhaust
system for restrictions and damage. Repair or replace
the exhaust system as needed.
NOTE: When the dryer is rst installed, this test should
be performed to alert you to any existing problems
with the exhaust ducts in your home. However, since the
test performed during normal operation provides more
accurate information on the condition of the exhaust
duct than does the installation test, the results of the two
tests may not be the same.
Do not interrupt the test cycle, as this could result in
inaccurate results.
Even if the LED is not blinking during the test cycle,
some restrictions may still be present in the exhaust
system. Refer to the Venting the Dryer section of
this guide for complete exhaust system and venting
requirements.
Avoid long runs or runs with multiple elbows or bends.
Excess or crushed
transition duct
Check for blockages and lint buildup.
Too many elbows or
exhaust too long
Lint
blockage
buildup or
Make sure the ductwork is not crushed or restricted.
Crushed
or
damaged
exhaust
INSTALLATION INSTRUCTIONSINSTALLATION INSTRUCTIONS