- 18 -
4. Insert the new exhaust lter cartridge
into the lter cover with the rubber seal
upward.
5. To replace the exhaust lter cover,
insert the two tabs on the cover into
the slots at the top of the lter chamber.
6. Rotate lter cover down until it snaps into
place.
EXHAUST FILTER CHANGING
EXHAUST FILTER - HEPA MEDIA
The exhaust lter cartridge must be
replaced when dirty. Replace the lter
when the entire surface area is covered
evenly. The lter CANNOT be washed as
it will lose its dust trapping ability.
NOTE: See REPLACEMENT PARTS for part
number and purchase details (page 5).
WARNING
Fire and/or Electrical Shock Hazard
Do not operate with a clogged exhaust
lter or without the exhaust lter
installed. Do not operate without lter
cover installed.
1. Push latch up to release the exhaust lter
cover from slot in canister.
2. Pull lter cover down and outward to
remove it from lter chamber in the canister.
3. Remove the exhaust lter cartridge from
the lter cover.