- 21 -
BRUSHROLL SERVICING
TO CHECK THE BRUSHES
When brushes are worn to the level of the
base support bars, replace the brushroll
assembly.
TO REPLACE BRUSHROLL ASSEMBLY
1. Remove the oor brush from the
PowerMate
®
.
2. Remove PowerMate
®
cover, belt and
brushroll assembly.
See “To Remove Belt” in BELT CHANGING
AND BRUSHROLL CLEANING (page 19).
3. Install new brushroll assembly.
4. Reinstall belt and PowerMate
®
cover.
See“To replace belt” in BELT CHANGING
AND BRUSHROLL CLEANING (page 20).
NOTE: See REPLACEMENT PARTS for part
number and purchase details (page 5).
Base
Support
Bar
Worn Brushes
New Brushes
WARNING
Electrical Shock Or Personal Injury
Hazard
Always turn o and unplug vacuum
cleaner
before performing maintenance
to the vacuum cleaner
. Failure to do so
could result in electrical shock or personal
injury from vacuum cleaner suddenly
starting.