Cleaning the lter and diesel tank.
Remove the lter on the diesel circuit and replace it.
Replace regularly (g. ).
Empty the diesel tank.
Using the drainage bung (g.
8), drain any impurities present
into a container.
Rinse the tank with clean diesel and close the drainage hole.
DESCALING
The appliance must be descaled regularly to avoid the risk of
calcium in the water building up in and blocking the water circuit
and coil.
This should be done by an authorised technical service
centre and will increase the efciency of the heat genera-
tor.
STORAGE
If the hot water generator is not used for long periods, unplug
from the mains socket and protect parts which might be dam-
aged by dust. Empty the water circuit and rinse with clean
water.
When used again, check there are no cracks or cuts in the
feed pipe.
If you decide to stop using the hot water generator, you should
render it inoperative by removing the electric power cable. Parts
which might constitute a danger, especially to children playing
with the appliance, should be made harmless.
The hot water generator is classied
as special waste. It must
be taken apart and divided into uniform sections which should
be disposed off according to legislation in force in the country
concerned.
Do not use the components removed as spare parts.
SCRAPPING
H.P. feed pipe l = .0 m
TECHNICAL CHARACTERISTICS
0 0 - 0/
Boiler volume l ,9 ,0
Min. ow rate l/min. 6 6
Max. ow rate l/min. 1 1
Working pressure bar 1 00-0
Water temp. °C 10° 10°
Heat input W 00 00
Heat output kW 6 88
Diesel tank l 18 18
Weight Kg 9 10
Noise level Lp dB (A) 69 69
STANDARD KIT
TROUBLESHOOTING
Problem
The appliance does not work.
Cause
No voltage.
Faulty cable or mains switch.
Remedy
Make sure there is voltage.
Contact the service centre.
Problem
When the thermostat reaches the
set temperature, the boiler
does not come on.
Cause
No diesel.
Clogged diesel lters.
Remedy
Check the
level of diesel in the fuel tank. Check the state of
cleanliness of the fuel intake circuit (presence of water). Replace
the circuit lter.
Problem
Water not hot enough.
Cause
Thermostat calibration.
Clogged lters.
Boiler coil blocked with scale.
Remedy
Check.
Clean diesel lters.
Contact the service centre.
Problem
Excessive smoking from ue.
Cause
No diesel.
Incorrect fuel.
Fuel contaminated with impurities or water.
Remedy
Fill diesel tank.
Clean diesel lters. Contact authorised service centre.
Empty the tank and clean thoroughly. Clean the various diesel
lters.