    Sydney LewisAug 12, 2025
    What to do if the Kesla Construction Equipment crane does not move?
    • B
      brianmilesAug 12, 2025
      If the crane does not move, there might be several reasons: * The oil tank may be empty. If this is the case, add oil. * The pressure connection might not be connected properly or could be faulty. Check the connection and replace the quick coupler if needed. * The pump may not be building up enough pressure. In this case, measure the pressure from the pressure end of the control valve and check the pump pressure relief valve.
  • S
    Shawn SteinAug 19, 2025
    Why is the Kesla 2010 crane moving a little bit or powerless?
    • F
      fhallAug 19, 2025
      If the crane moves a little or seems powerless, it could be due to: * A return connector that is not properly connected or is faulty. Check the connection and measure the return pressure. * The main release of the crane or the pump pressure relief valve is faulty or dirty. Measure the pressure from the pressure end of the control valve and replace the pressure relief valve if necessary.
  • R
    Ralph WernerAug 27, 2025
    What to do if the Kesla 2010 Construction Equipment boom is lowered at normal load?
    • T
      Tiffany GarciaAug 27, 2025
      If the boom is lowered at normal load, consider these potential causes: * The pressure relief valve of the relevant operation is leaking: Replace the pressure relief valve. * The cylinder seal is leaking: Replace the seals. * The valve spool is leaking: The functionality falls under the load and the cylinder heats up when putting a load on it.
  • J
    Jeffrey SanchezSep 2, 2025
    What to do if one option is powerless on Kesla 2010 Construction Equipment?
    • B
      Bobby MarquezSep 3, 2025
      If one option is powerless, it might be because the spool specific pressure release valve is faulty or dirty. To resolve this, measure the pressure of the relevant operation and replace the pressure relief valve if necessary.