Model | C55 |
---|---|
Category | Boiler |
Output | 55 kW |
Fuel Type | Natural Gas |
Warranty | 5 years |
Boiler Type | Condensing |
Mounting | Wall Mounted |
Type | Commercial |
Describes the Keston C40 and C55 as high efficiency condensing boilers for central heating and indirect sanitary hot water.
Recommends annual servicing by a competent person and notes no user-serviceable parts inside.
Specifies minimum clearances required around the boiler for installation and servicing.
Instructions for cleaning the boiler casing using a dry or damp cloth.
Checks for gas supply and electrics, setting heating controls to call for heat.
Explains setting temperatures for two zones and how the boiler responds.
Details the display codes indicating the boiler's ignition and operation stages.
Ensures condensate line, air intake, and flue exhaust terminals remain unobstructed.
Details the integral frost protection thermostat and need for pipe insulation.
Lists common error codes (E00-E11) and their descriptions for fault diagnosis.
Lists advanced error codes (E18-E44) related to flow, return, and pressure issues.
Immediate actions for a suspected gas leak: turn off appliance/gas, contact gas region.
Consult installer or service engineer for breakdowns, advising fault display and description.
Details the Benchmark Log Book for recording installation, commissioning, and service visits.
Information on using CORGI registered installers for installation and servicing.