Sociable Remark

DISPOSAL

Information on proper disposal of the dehumidifier in European countries, emphasizing collection and special treatment.

SAFETY PRECAUTIONS

WARNING

Safety warnings indicating the possibility of death or serious injury if instructions are ignored.

CAUTION

Safety cautions indicating the possibility of injury or property damage if instructions are not followed.

Electrical Information

Details about the unit's nameplate, grounding requirements, and proper electrical connections.

CONTROL PADS ON THE DEHUMIDIFIER

Control pads

Explanation of the function of each button on the dehumidifier's control panel.

Humidity Set Control Pads

How to adjust the desired humidity level using the up/down pads.

TIMER Set Control Pads

Instructions for setting the auto start and auto stop timer functions.

Display

Information on what the display shows, including humidity levels and error codes.

Other features

Details on features like Bucket Full Light, Auto Shut Off, Auto Defrost, and wait times.

Auto-Restart

Explanation of the unit's auto-restart function after a power interruption.

Setting the Timer

Detailed steps on how to set the auto start and auto stop timer functions.

IDENTIFICATION OF PARTS

Front

Identification of parts located on the front of the dehumidifier unit.

Rear

Identification of parts located on the rear of the dehumidifier unit.

Accessories

List and identification of included accessories such as drain hose and adaptor.

OPERATING THE UNIT

Positioning the unit

Guidelines for placing the dehumidifier in a suitable location for optimal performance and safety.

When using the unit

Initial usage instructions, operating environment, and connection requirements.

Removing the collected water

Instructions on how to empty the water bucket and use the continuous draining feature.

Continuous draining

Steps for setting up and using the continuous drainage option with a water hose.

CARE AND MAINTENANCE

Clean the Grille and Case

Instructions for cleaning the exterior of the dehumidifier unit.

Clean the bucket

Steps for cleaning the water collection bucket to prevent mold and bacteria.

Clean the air filter

Instructions on how to remove, wash, and re-install the air filter.

When not using the unit for long time periods

Guidance on storing the dehumidifier properly when not in use for extended periods.

TROUBLESHOOTING TIPS

Unit does not start

Common causes and checks for when the dehumidifier fails to start.

Dehumidifier does not dry the air as it should

Checks and potential causes if the unit is not effectively removing moisture.

The unit makes a loud noise when operating

Possible reasons for excessive noise during operation and checks to perform.

Frost appears on the coils

Explanation of frost on coils and the unit's auto defrost feature.

Water on floor

Troubleshooting steps for leaks or water on the floor.

ES, AS,P2 and EC appear in the display

Information on error codes displayed and where to find more details.

Air Conditioner Warranty

Warranty Service

Details on how to obtain warranty service and contact information.

NORMAL RESPONSIBILITIES OF THE CONSUMER*

Consumer's responsibilities regarding proper use, installation, and maintenance.

EXCLUSIONS

Conditions and circumstances not covered by the product warranty.

Summary

Sociable Remark

DISPOSAL

Information on proper disposal of the dehumidifier in European countries, emphasizing collection and special treatment.

SAFETY PRECAUTIONS

WARNING

Safety warnings indicating the possibility of death or serious injury if instructions are ignored.

CAUTION

Safety cautions indicating the possibility of injury or property damage if instructions are not followed.

Electrical Information

Details about the unit's nameplate, grounding requirements, and proper electrical connections.

CONTROL PADS ON THE DEHUMIDIFIER

Control pads

Explanation of the function of each button on the dehumidifier's control panel.

Humidity Set Control Pads

How to adjust the desired humidity level using the up/down pads.

TIMER Set Control Pads

Instructions for setting the auto start and auto stop timer functions.

Display

Information on what the display shows, including humidity levels and error codes.

Other features

Details on features like Bucket Full Light, Auto Shut Off, Auto Defrost, and wait times.

Auto-Restart

Explanation of the unit's auto-restart function after a power interruption.

Setting the Timer

Detailed steps on how to set the auto start and auto stop timer functions.

IDENTIFICATION OF PARTS

Front

Identification of parts located on the front of the dehumidifier unit.

Rear

Identification of parts located on the rear of the dehumidifier unit.

Accessories

List and identification of included accessories such as drain hose and adaptor.

OPERATING THE UNIT

Positioning the unit

Guidelines for placing the dehumidifier in a suitable location for optimal performance and safety.

When using the unit

Initial usage instructions, operating environment, and connection requirements.

Removing the collected water

Instructions on how to empty the water bucket and use the continuous draining feature.

Continuous draining

Steps for setting up and using the continuous drainage option with a water hose.

CARE AND MAINTENANCE

Clean the Grille and Case

Instructions for cleaning the exterior of the dehumidifier unit.

Clean the bucket

Steps for cleaning the water collection bucket to prevent mold and bacteria.

Clean the air filter

Instructions on how to remove, wash, and re-install the air filter.

When not using the unit for long time periods

Guidance on storing the dehumidifier properly when not in use for extended periods.

TROUBLESHOOTING TIPS

Unit does not start

Common causes and checks for when the dehumidifier fails to start.

Dehumidifier does not dry the air as it should

Checks and potential causes if the unit is not effectively removing moisture.

The unit makes a loud noise when operating

Possible reasons for excessive noise during operation and checks to perform.

Frost appears on the coils

Explanation of frost on coils and the unit's auto defrost feature.

Water on floor

Troubleshooting steps for leaks or water on the floor.

ES, AS,P2 and EC appear in the display

Information on error codes displayed and where to find more details.

Air Conditioner Warranty

Warranty Service

Details on how to obtain warranty service and contact information.

NORMAL RESPONSIBILITIES OF THE CONSUMER*

Consumer's responsibilities regarding proper use, installation, and maintenance.

EXCLUSIONS

Conditions and circumstances not covered by the product warranty.

Keystone KSTAD50B Specifications

General IconGeneral
BrandKeystone
ModelKSTAD50B
TypeDehumidifier
Dehumidification Capacity50 pints per day
Moisture Removal50 pints per day
Energy Star RatedYes
Voltage115V
Coverage Area3000 square feet
Weight40.8 lbs