The counter functions F01, F02, F03 and F04 are measured by using the following formulas:
measurement value = count *A_B+C
A, B: ratio factor. Set the ratio factor to convert the count value into the unit of measurement.
C: the initial value of the counter, so that the measurement starts with the desired value.
For example, the encoder with output pulse 1000p/r is used in the measurement of sheet metal length in
the following figure. The circumference of the roll is 200 mm. Setting parameters: When A = 2000, B =
1000, C = 0, DP = 1, the display value unit of the instrument is mm, and 1 digit is reserved after
decimal point.
Sheet Length Yield Count
Fabric and Paper Length