FALSE ALARM CONTROL
To use the False Alarm Control:
Press and release the test button during an unwanted alarm. The alarm should
stop within ten seconds. This means the smoke alarm is in False Alarm Control.
If the smoke alarm does not go into False Alarm Control and continues to sound
its loud alarm horn, or if it initially goes into False Alarm Control then resounds the
alarm, the smoke is too heavy and could be a dangerous situation— take emer-
gency action.
TESTING THE SMOKE ALARM
WARNING
•
Test each smoke alarm to be sure it is installed correctly and operating properly.
•
Test all smoke alarms in an interconnected system after installation.
•
The Push-to-Test button accurately tests all functions. DO NOT use an open
flame to test this smoke alarm. You may ignite and damage the smoke alarm or
your home.
•
Test smoke alarms weekly and upon returning from holiday or when no one has
been in the household for several days.
•
Stand at arm’s length from the smoke alarm when testing. The alarm horn is
loud to alert you to an emergency and can be harmful to hearing.
Test all smoke alarms weekly by doing the following:
1. Check Push-to-Test button. A constant green light indicates the smoke alarm is
receiving 230V AC, 50Hz power. A red flashing LED about once a minute veri-
fies operation. The red flashing LED also verifies that a working battery is pres-
ent.
2. Firmly depress the Push-to-Test button for at least five (5) seconds. The smoke
alarm will sound a loud beep about four (4) times a second. The alarm may
sound for up to 10 seconds after releasing the Push-to-Test button.
NOTE: If smoke alarms are interconnected, all smoke alarms should sound an
alarm within three seconds after any test button is pushed and the tested
smoke alarm sounds.
3. If smoke alarm does not sound, turn off power at main fuse box or circuit
breaker and check wiring. Retest smoke alarm.
DANGER: If alarm horn sounds, and smoke alarm is not being
tested, the smoke alarm is sensing smoke. THE
SOUND OF THE ALARM HORN REQUIRES YOUR
IMMEDIATE ATTENTION AND ACTION.
MAINTENANCE AND CLEANING
In addition to weekly testing, this alarm also require periodic battery replacement.
Regularly clean smoke alarm to remove dust, dirt, and debris.
WARNING: Alarm comes equipped with a dust cover, which
prevents dust and debris from damaging the unit
during construction or remodeling. Remove dust
cover before operation. Alarm will not operate
properly while covered.
DANGER: ELECTRICAL SHOCK HAZARD. Turn off main power
at fuse box or consumer unit by removing fuse or
switching appropriate circuit breaker to OFF position
before replacing battery or cleaning smoke alarm.
BATTERY REPLACEMENT
CAUTION: Danger of explosion if battery is incorrectly replaced.
Always turn off power to smoke alarm before replacing battery. Replace battery at
least once a year or immediately when the low battery signal sounds once a minute,
even though the smoke alarm is receiving AC power.
Use only the following batteries as replacements in this smoke alarm:
Eveready 216, 522, 1222; Duracell MN 1604; or Ultralife U9VL-J
Replace only with the same or equivalent battery type recommended by the manu-
facturer. Discard used batteries safely according to manufacturer's instructions.
TEST THE ALARM FOR CORRECT OPERATION USING THE TEST BUTTON
WHENEVER THE BATTERY IS REPLACED.
WARNING: DO NOT USE ANY OTHER TYPE OF
BATTERY, EXCEPT AS SPECIFIED IN THIS MANUAL.
DO NOT USE RECHARGEABLE BATTERIES.
1. Turn off power to smoke alarm at main service panel.
2. Slide battery door open as shown in the illustration.
3. Remove drained battery from compartment and discard.
4. Install a fresh 9-volt battery.
5. Slide battery door closed.
6. Turn on power and test smoke alarm using Push-
to-Test button.
CLEANING
Clean the smoke alarm at least once a month to remove
dust, dirt, or debris. Always turn off power to smoke alarm
before cleaning.
•
Using the soft brush or wand attachment to a vacuum
cleaner, vacuum all sides and cover of smoke alarm. Be sure all the vents are free
of debris.
•
If necessary, turn off power and use a damp cloth to clean smoke alarm cover.
IMPORTANT: Do not attempt to remove the cover or clean inside the smoke alarm.
THIS WILL VOID YOUR GUARANTEE.
REPAIR
CAUTION: Do not attempt to repair this smoke alarm. Doing so will
void your guarantee.
If smoke alarm is not operating properly, see “Troubleshooting”. If necessary and if
still under guarantee, return smoke alarm to Kidde. Pack it in a well-padded carton
and send, postage prepaid to Kidde address at the end of this manual.
If the smoke alarm is no longer under guarantee, have a licensed electrician
replace the smoke alarm immediately with a comparable Firex brand smoke alarm.
PRACTICE FIRE SAFETY
If the smoke alarm sounds its alarm horn, and you have not pushed the test
button, it is warning of a dangerous situation. Your immediate response is nec-
essary. To prepare for such occurrences, develop family escape plans, discuss
them with ALL household members, and practice them regularly.
•
Expose everyone to the sound of a smoke alarm and explain what the
sound means.
•
Determine TWO exits from each room and an escape route to the outside
from each exit.
•
Teach all household members to touch the door and use an alternate exit if
the door is hot. INSTRUCT THEM NOT TO OPEN THE DOOR IF THE
DOOR IS HOT.
•
Teach household members to crawl along the floor to stay below danger-
ous smoke, fumes, and gases.
•
Determine a safe meeting place for all members outside the building.
WHAT TO DO IN CASE OF A FIRE
1. Don’t panic; stay calm.
2. Leave the building as quickly as possible. Touch doors to feel if they
are hot before opening them. Use an alternate exit if necessary. Crawl
along the floor, and DO NOT stop to collect anything.
3. Meet at a pre-arranged meeting place outside the building.
4. Call the fire brigade from OUTSIDE the building.
5. DO NOT GO BACK INSIDE A BURNING BUILDING. Wait for the fire
brigade to arrive.
These guidelines will assist you in the event of a fire. However, to reduce the
chance that fires will start, practice fire safety rules and prevent hazardous
situations.
TROUBLESHOOTING
DANGER: Always turn off power at main fuse box or consumer
unit before taking trouble- shooting action.
WARNING: DO NOT disconnect battery or mains power to
quiet an unwanted alarm. This will remove your
protection. Fan the air or open a window to
remove smoke or dust. You may also use the false
alarm control feature, you may also use the False
Alarm Control feature to quiet unwanted alarms.
WARRANTY
Kidde warrants to the original consumer purchaser each new smoke alarm to
be free from defects in material and workmanship under normal use and serv-
ice for a period of six (6) years in the United Kingdom and Republic of Ireland
from date of purchase. Kidde agrees to repair or replace, at its option, any
defective smoke alarm, provided that it is returned with postage prepaid and
with proof of purchase date to Kidde. This warranty does not cover damage
resulting from accident, misuse or abuse or lack of reasonable care of the
product. This warranty is in lieu of all other express warranties, obligations or
liabilities. THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FIT-
NESS FOR A PARTICULAR PURPOSE ARE LIMITED TO A PERIOD OF SIX
(6) YEARS FROM PURCHASE DATE. Some states do not allow
limitations on how long an implied warranty lasts, so the above limitations may
not apply to you. IN NO CASE SHALL KIDDE BE LIABLE FOR ANY INCI-
DENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF THIS OR ANY
OTHER WARRANTY, EXPRESS OR IMPLIED, WHATSOEVER, EVEN IF THE
LOSS OR DAMAGE IS CAUSED BY ITS NEGLIGENCE OR FAULT. Some
states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you. This
warranty gives you specific legal rights, and you may also have other legal
rights which vary from state to state.
Return units freight prepaid to your local reseller. For information on your local
reseller in the U.K. and Republic of Ireland, contact:
KIDDE SAFETY EUROPE LIMITED
Mathisen Way
Colnbrook, Berkshire SL3 0HB
United Kingdom
Tel.: +44 (0) 1753 685148
www.smoke-alarms.co.uk
5
6
7
8
!
!
!
!
!
!
!
!
!
PROBLEM SOLUTION
Smoke alarm does not 1. Check that AC power
sound when tested. is turned on. Green LED
should be illuminated.
2. Turn off power. Remove
smoke alarm from
mounting plate and:
a. check that connector
plug is securely
attached.
b. check that battery is
properly attached to
connector.
3. Clean smoke alarm.
Smoke alarm sounds 1. Hire an electrician to
unwanted alarms when move smoke alarm to a
residents are cooking, new location. See
taking showers, etc. "SMOKE ALARM
PLACEMENT"
Interconnected smoke 1. Press and hold test
alarms do not sound when button for at least
system is tested. three seconds after the
first unit sounds.
2. Hire an electrician to
ensure smoke alarms
are properly connected.
NOTE: Push test but-
ton for at least five (5)
seconds while testing!
1280-7201-00
Kidde strongly recommends that both ionization and photoelectric smoke
alarms be installed to insure maximum detection of the various types of fires
that can occur within the home. Ionization sensing alarms may detect invis-
ible fire particles (associated with fast flaming fires) sooner than photoelec-
tric alarms. Photoelectric sensing alarms may detect visible fire particles
(associated with slow smoldering fires) sooner than ionization alarms.