DC Powered in Battery Backup Operation
D
isplay Shows Alarm Sound Unit Status Unit Condition Recommendation
If at any time you test the alarm and it does not perform as described,
have it replaced immediately.
1 “chirp” every
60 seconds
Unit in trouble
alarm. Mode
will continue for
approximately 7
hours. WILL
NOT DETECT
CO.
Operation on
battery backup
and battery is fully
discharged.
Confirm battery
connection is fully
seated & oriented
properly. Connect to
AC power to fully
charge battery.
Call Kidde customer
service at
1-800-880-6788 if
condition continues.
Flashing dot
once every 60
seconds
None Unit is not
operational.
WILL NOT
DETECT CO.
Battery is
disconnected or
missing
Confirm battery
connection is fully
seated & oriented
properly. Connect to
AC power to fully
charge battery.
Call Kidde customer
service at
1-800-880-6788 if
condition continues.
None
6. Operating Characteristics
Peak Level Memory
When the Peak Level button is pressed and held, the display shows the
highest CO reading taken by the CO alarm since its last reset or power
up. The Peak Level display feature will display levels between 11-999
PPM. Although the Peak Level feature will display levels below 30 PPM,
these levels will not result in an alarm no matter how long the device is
exposed to these levels. The Peak Level feature is helpful in identifying if
you have had a CO reading since resetting the alarm.
Concentrations of CO between 1 and 30 PPM can often occur in
normal, everyday conditions. Concentrations of CO below 30 PPM may
be an indication of a transient condition that may appear today and
never reappear. Some CO conditions may start out as low level leaks but
could develop into CO concentrations that may become harmful.
Peak Level Memory Reset
Press the Peak Level button; with the button still pressed, press the
Test/Reset button for two seconds and release. The number on the
display will turn to “0”, the memory will be cleared and the alarm will
begin monitoring for CO. The Peak Level memory is also reset when the
unit loses power.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kidde KN-COPP-3-RC and is the answer not in the manual?

Kidde KN-COPP-3-RC Specifications

General IconGeneral
BrandKidde
ModelKN-COPP-3-RC
CategoryCarbon Monoxide Alarm
LanguageEnglish

Related product manuals