of smokeless fuels, sweep at east once a year; for wood and other fuels, at least
twice a year. If the stove is fitted in place of an open fire, then the chimney should
be swept one month after installation to clear any soot falls which may have
occurred due to the difference in combustion between the stove and the open fire.
We suggest users buy replacement and spare parts only from our dealers in
your local place.
Trouble clearing
No Fire can be burnt
Please check the following measures:
A proper fuel is being used.
The air inlet is unobstructed.
Chimneys and flueways are clear
Sufficient air supply is into the room.
No extractor fan is working in the same room as the stove.
Fire blazing out of control
Please Check:
A suitable fuel is being used.
The doors are tightly closed.
The air controls are all in the closed position.
The primary air control flap is not wedged in the open position.
The glass retaining clips are not loose.
The door rope seals are in good condition