Model Number FDV350
Free Standing Direct Vent Gas Stove
(Field Convertible to Vented Stove)
Model Numbers:
FDV350N, FDV350NE, FDV350NE2, FDV350LP, FDV350LPE, FDV350LPE2
Certified to:
ANSI Z21.88-2017 • CSA 2.33-2017
VENTED GAS FIREPLACE HEATER
-Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
-WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the fire department
-Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
Installation Instructions
This appliance may be installed in an aftermarket, permanently located, manufactured home (USA
only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified kit is used.
INSTALLER: Leave this manual with the
appliance.
CONSUMER: Retain this manual for
future reference.
A Division of R-Co. Inc.
2340 Logan Ave.
Winnipeg, Manitoba Canada
R2R 2V3 Ph.: (204) 632-1962
Printed in Canada October 12, 2018
Part# 350-MAN17
For Propane Horizontal
installations the venting must
be an additional one foot
above the minimum vertical
rise off the flue before going
horizontal.

Table of Contents

Other manuals for Kingsman FDV350

Questions and Answers

  • A
    Amy RodriguezAug 9, 2025
    Why won't the pilot light stay lit on my Kingsman Stove?
    • C
      Craig RivasAug 10, 2025
      If the pilot light on your Kingsman Stove won't stay lit after following the lighting instructions, it could be due to a defective thermocouple. Ensure the pilot flame impinges on both the generator and thermocouple. Try cleaning and adjusting the pilot for maximum flame impingement. If it still won't hold, replace the thermocouple, tightening it by hand and then an additional 1/8 turn. If replacing the thermocouple doesn't solve the issue, the valve magnet may be defective, and the valve should be replaced.
  • E
    Erin MillerAug 14, 2025
    How to fix a Kingsman Stove spark igniter that won't light?
    • E
      ewilsonAug 14, 2025
      If your Kingsman Stove's spark igniter isn't lighting, it could be due to a defective or misaligned electrode at the pilot. Check for a spark at the electrode and pilot. If there's no spark and the electrode wire is properly connected, replace the igniter. Alternatively, the igniter itself (push-button) might be defective. Try lighting the pilot with a match. If it lights, turn off the pilot and try the red button again. If it still doesn't light, ensure the gap at the electrode and pilot is between 1/8” to 1/4” for a strong spark.
  • M
    Mallory RichardsonAug 25, 2025
    Why does my Kingsman Stove have frequent pilot outages?
    • M
      Michele MillerAug 26, 2025
      Frequent pilot outages on your Kingsman Stove could be due to a pilot flame that is either too low or too high, causing the pilot safety to drop out. To resolve this, clean and/or adjust the pilot flame to ensure maximum flame impingement on the generator and thermocouple.
  • V
    Veronica BradfordAug 29, 2025
    What causes the flame to lift off the burner and go out quickly on a Kingsman FDV350?
    • J
      Jessica JohnsonAug 29, 2025
      If the flame lifts off the burner and goes out in less than 30 seconds on your Kingsman Stove, the inner 4” liner may have come off the flue or termination, causing the flame to starve for oxygen. Reattach the 4” liner to the flue or termination using screws, silicone, and clamps as described in the manual.
  • R
    richard15Sep 3, 2025
    Why does the flame lift off the burner on one side of my Kingsman FDV350 Stove?
    • X
      xwongSep 3, 2025
      If the flame lifts off the burner on one side while the rest of the flame remains lit on your Kingsman Stove, it's likely due to improper installation of the firebrick, possibly leaning. Ensure the firebrick is positioned correctly against the firebox walls and secured using brick clips attached to the inner side of the firebox.
  • A
    Ariana RodriguezNov 18, 2025
    What to do if Kingsman FDV350 Stove pilot is burning but no gas to burner?
    • D
      deanbartonNov 18, 2025
      If the pilot is burning on your Kingsman Stove, the valve knob and wall switch are 'ON,' but there's no gas to the burner, several issues could be at play. First, the wall switch or its wiring might be faulty. Check the switch and wires for secure connections. You can use a jumper wire across the terminals at the wall switch; if the burner ignites, the switch is defective and needs replacement. If the switch is fine, jump the wires across the wall switch wires at the valve. If the burner then comes on, the wires are faulty or have bad connections. Another possibility is that the generator isn't producing enough voltage. Test the generator with a millivolt meter at the gas valve terminals; it should read a minimum of 325 millivolts with the valve knob depressed in the pilot position and the...

Kingsman FDV350 Specifications

General IconGeneral
VentingDirect Vent
Ignition SystemElectronic Ignition
MaterialSteel
Ignition TypeElectronic
TypeFreestanding Stove
Fuel TypeNatural Gas or Propane
Weight170 lbs
Log SetCeramic Fiber