EasyManua.ls Logo

Kingspan SHE TRZ Plus 2A User Manual

Kingspan SHE TRZ Plus 2A
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Kingspan
SHE Control Panel TRZ Plus 2A
and TRZ Plus Comfort
Technical Manual
Compact Control Panel 2A and Compact Control Panel 2A/M
Light + Air
UK & Republic of Ireland
Question and Answer IconNeed help?

Do you have a question about the Kingspan SHE TRZ Plus 2A and is the answer not in the manual?

Kingspan SHE TRZ Plus 2A Specifications

General IconGeneral
BrandKingspan
ModelSHE TRZ Plus 2A
CategoryControl Panel
LanguageEnglish

Summary

Equipment Overview / Function

Scope of Delivery

Safety Instructions

General Safety Guidelines

Covers regulations, transport, installation, operation, repair, and maintenance.

Maintenance and Repair Procedures

Details annual checks, authorized repairs, and essential maintenance.

Electrical Safety

Electrical Safety Guidelines

Adherence to electrical safety laws, standards, and manufacturer guidelines for wiring.

Mechanical Safety

Mechanical Safety Precautions

Covers window safety, crush hazards, accident prevention laws, and environmental conditions.

Routing of Cables

Cable Selection and Diagrams

Guidance on selecting cable types and wiring examples for control panel connections.

Description of Function

Panel Functions Overview

Covers SHE/ventilation, drive control, self-monitoring, and power backup features.

Manual and Automatic Activation

How manual call points and detectors trigger window opening/closing.

Daily Ventilation and Reset Procedures

Operation of daily ventilation and resetting automatic detectors.

Function Description: Operation Modes

Automatic Ventilation Control

Automatic window closing on timer or failure, and related functions.

LED Display Indicators

Explanation of status LEDs for operation, SHE activation, and malfunctions.

Wind/Rain Detector Integration

How wind/rain detectors trigger automatic window closure.

Cable Length and Cross-Section Determination

Cable Length Diagram for Drives

Graph to determine necessary cable length based on drive current.

Cable Cross-Section Calculation

Formula and examples for calculating cable cross-sections and selecting types.

Possible Connections

System Component Interfacing

Lists various devices connectable to the control panel, e.g., drives, detectors, call points.

Additional Module Integration

Details connections for optional modules like wind-rain detectors and alarm systems.

Connection Testing Procedures

Wind/Rain Detector Function Test

Verifying wind/rain detector response to environmental changes and triggering window closure.

SHE Manual Call Point Test

Checking SHE manual call point functions, activation, and reset operations.

Connecting Diagram: Mains and Drives

Mains Power Wiring

Diagram for connecting 230V AC mains supply to the control panel.

Drive Unit Wiring

Diagrams for connecting 24V DC drives, including single, multiple, and junction box configurations.

Connecting Diagram: Magnetic Clamps and Locking

Magnetic Locking Wiring

Diagrams for connecting magnetic locks that hold windows open or closed via spring force.

Magnetic Clamp Wiring

Diagrams for connecting magnetic clamps used for door holding or closing mechanisms.

Connecting Diagram: Vent Switch

Vent Switch LTA11 Connections

Wiring diagrams for connecting LTA11 vent switches, both single and multiple units.

Vent Switch LTA25 Connections

Wiring diagrams for connecting LTA25 vent switches, including jumper settings.

Connecting Diagram: SHE Manual Call Point

Single SHE Call Point Wiring

Diagram for wiring a single SHE manual call point with a monitoring resistor.

Multiple SHE Call Point Wiring

Diagrams for connecting multiple SHE manual call points in series for system expansion.

Connecting Diagram: Smoke Detector

Single Smoke Detector Wiring

Diagram for connecting a single smoke detector and its monitoring resistor.

Multiple Smoke Detector Wiring

Diagrams for connecting multiple smoke detectors in a series loop with monitoring.

Connecting Diagram: Fire Alarm System (FAS)

FAS Module Wiring

Diagrams for connecting the Fire Alarm System module (UEB3-1K-AE) with and without smoke detectors.

Connecting Diagram: Buzzer and Signal Lamp

Alarm Buzzer Connection

Wiring diagram for connecting an alarm buzzer to the control panel output terminals.

Signal Lamp Connection

Wiring diagram for connecting a signal lamp to the control panel output terminals.

Connecting Diagram: Wind/Rain Detector

Wind/Rain Detector Wiring

Diagrams for connecting wind/rain detectors and setting up jumpers and relay contacts.

Connecting Diagram: Potential Free Contacts

SHE Activation & Malfunction Contacts

Connecting potential-free contacts for SHE activation and malfunction messages.

Connecting Diagram: Selector Switch, Sensor, Vent Switch

Two Temperature Sensor Variant

Wiring for selector switch and two temperature sensors to control window hysteresis.

One Temperature Sensor Variant

Wiring for selector switch and one temperature sensor for automatic window control.

Connecting Diagram: Multisensor for Room Air

Multisensor Variant 1 Wiring

Standard wiring for multisensor power and data connection to the panel.

Multisensor Variant 2 Wiring

Wiring multisensor via WRMAS for wind-rain detector power supply.

Overall Connection Diagram

System Component Connectivity Overview

Comprehensive diagram showing all major component connections to the control panel.

Multisensor Connection Variants

Illustrates the two connection variants for the multisensor unit.

Function of DIP-Switches

DIP-Switch Settings Overview

List of functions controlled by DIP-switches 1 through 12.

DIP-Switch 1-3 Functions

Detailed functions for DIP-switches 1, 2, 3, and the combined 3+9 setting.

DIP-Switch Functions: 3+10 to 9

DIP-Switch 3+10: Power Failure Ventilation

Configuration for automatic ventilation upon main power failure.

DIP-Switch 4: Fire Alarm System Integration

Integration with FAS for open/reset signals and SHE activation.

DIP-Switch 5-9 Functions

Functions for pre-alert, actuation limit, malfunction, SHE reset, and inching mode.

DIP-Switch Functions: 10 to 12 and Combinations

DIP-Switch 10: STOP Function

STOP function for key-operated buttons and safety for power-operated windows.

DIP-Switch 11: Detector Monitoring

Enabling detector monitoring with a 10kΩ resistor.

DIP-Switch 12: Automatic Closure

Automatic window closure after a set time following ventilation commands.

Special Function Combinations

Details on switch combinations for specific operating modes like SHE/ventilation with stroke limits.

Start Up Procedure and Trial Run

Pre-Startup Checks and Visual Display

Initial checks of connections, ferrite core, battery, and LED status indicators.

Vent Switch Testing

Testing vent switch operations for opening, closing, and stopping window movements.

Troubleshooting Notes

Guidance on interpreting LED indicators and common issues like loose connections or faulty switches.

Testing System Functions

SHE Manual Call Point Test

Verifying SHE manual call point activation, LED indications, and acoustical signals.

Emergency Power Supply Test

Testing system behavior during mains failure, checking LEDs and automatic window closure.

Automatic Detector and Ventilation Tests

Testing automatic detectors and automatic ventilation control based on DIP-Switch settings.

Testing Additional Functions

Wind/Rain Detector and Sensor Test

Testing wind/rain detector response to environmental stimuli and verifying window closure.

Buzzer / Signal Light Test

Testing activation of audible and visual alarms upon SHE activation.

Troubleshooting Common Issues

Addresses issues like reversed vent switch function, no function, or mains/fuse problems.

Troubleshooting

LED Display and Malfunction Diagnosis

Diagnosing issues based on LED status and interpreting malfunction beep codes.

Maintenance Timer and Signal Indicators

Understanding maintenance timer status and indicator lamps for wind/rain signals.

Maintenance

Regular Servicing and Checks

Requirements for annual checks, cleaning, tightening, and trial runs for SHE systems.

Equipment Repair and Parts Policy

Procedures for repairing defective equipment using only original spare parts.

System Deactivation Procedure

Steps to take the SHE system out of order by disconnecting mains and battery fuse.

Dimensional Drawings

TRZ Plus Unit Dimensions

Provides overall dimensions and mounting hole details for TRZ Plus 2A and Comfort units.

TRZ Plus Interface Layout

Shows the front panel layout for TRZ Plus 2A and TRZ Plus Comfort units.

Dimensional Drawings: Compact Panels

Compact Panel 2A Dimensions

Dimensions and mounting details for the plastic housing compact control panel.

Compact Panel 2A/M Dimensions

Dimensions and mounting details for the metal housing compact control panel.

Assembly Guidelines

General Installation Recommendations

Install in dry rooms, accessible locations, avoid projections, and ensure secure fixing.

Assembly: TRZ Plus and Compact Panel 2A

TRZ Plus Mounting and Battery Installation

Steps for mounting TRZ Plus units, setting height, and installing batteries correctly.

Compact Panel 2A Assembly

Wall mounting, housing fixation, and correct use of the ventilation plug.

Assembly: Compact Panel 2A/M

Compact Panel 2A/M Wall Mounting

Steps for mounting the metal housing panel and ensuring visibility and accessibility.

Rechargeable Battery Installation

Installing rechargeable batteries using velcro tapes and connecting them with correct polarity.

Service Port Software: Overview

General Information and Connection

Using PC interface for parameter adjustment, software/firmware dependency, and connection cable.

Configuration Screen and Info Page

Interface for settings, system info, factory defaults, and error display.

Service Port Software: Configuration Options

Automatic Ventilation Adjustment

Setting automatic ventilation time and its behavior with vent switch operation.

Maximum Opening Time Setting

Configuring stroke limitation by run time for the OPEN direction.

Pole Change Time Setting

Adjusting pause time for motor output polarity changes in milliseconds.

Service Port Software: Maintenance Counter

Maintenance Counter Enable/Disable

Password-protected activation/deactivation of the maintenance counter via the service interface.

Maintenance Counter Interface

User interface for viewing next planned service event and current service status.

Technical Data: Electrical Properties

Power Supply Specifications

Details on voltage, power consumption, and energy sources for primary and secondary supplies.

Output Specifications

Output voltage, current, ripple, and power for drives, clamps, and call points.

Cable Monitoring and Call Point Output

Specifications for cable monitoring functions and call point output power.

Technical Data: Outputs and Conditions

Alarm Unit, Buzzer/Lamp Outputs

Specifications for automatic alarm unit, buzzer, and signal lamp outputs.

Mechanical Properties and Dimensions

Weight and dimensions of the control panels.

Installation and Ambient Conditions

Temperature range, installation type, function retention, and IP protection ratings.

Technical Data: Certifications, Material, Options

Authorisations and Certifications

CE compliance, class of protection, and type testing compliance details.

Material, Colour, and Features

Housing material, colour options, and halogen/silicon-free properties.

Optional Modules and Battery Duty

Specifications for TRZ WRMAS modules and consumer obligations for battery disposal.

Contact Information

UK Contact Details

Kingspan Light + Air contact information for the United Kingdom.

Ireland Contact Details

Kingspan Light + Air contact information for the Republic of Ireland.

Related product manuals