KINROAD 150 SERVICE MANUAL VERSION 1, DEC., 2005
65
Connect the positive cable first, and then connect the negative cable.
BATTERY OPEN-CIRCUIT VOLTAGE INSPECTION
Disconnect the cable on the battery terminals.
Measure the voltage between the two poles of the battery.
Full charging 13.1V
Under charging 12.3V
BATTERY CHARGING
Lift the battery out of the vehicle.
Connect the positive pole of the charger with the positive pole of the battery.
Connect the negative pole of the charger with the negative pole of the battery.
Charge the battery for the charging time marked on the battery.
Measure the voltage 30 minutes after charging is finished, and it should reach the specified value;
otherwise it needs recharging.
Normal 0.7A
Charging current
Fast 3.0A
Normal 5-10 hours Charging time
Fast 30 minutes
Charging result Open-circuit voltage
>=12.8V
PRIMARY COIL
z Disconnect the negative pole first, and then the positive pole.
z Do not use fast charging unless it is emergent.
z No smoking or open fire near the battery when charging.
z At the beginning or the end of charging, turn off the charger first to avoid the connecting part
arcing.