9.3 Adjustment
Adjust the clearance between trigger and the projection part of rotor.
Trigger clearance 0.50-0.75mm
Insert a feeler gauge between the trigger and the projection part of the rotor; loosen the trigger fixed
plate bolt to adjust the clearance slightly. Never move the plastic part of trigger, to avoid it separates from
the fixed plate and damages the trigger.