40
PERFORMANCE DATA SHEET
Water Filtration System
Model P9WB2L/P9RFWB2L/EDR2RXD1 Capacity 200 Gallons (757 Liters)
This system has been tested according to NSF/ANSI Standards 42, 53, 401, and CSA B483.1 for the reduction of the substances listed
below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to
the permissible limit for water leaving the system, as specied in NSF/ANSI Standards 42, 53, 401, and CSA B483.1.
Substance Reduction
Aesthetic Effects
Inuent Challenge
Concentration
Maximum Permissible
Product Water Concentration
Average% Reduction
Chlorine Taste/Odor Particulate
Class I*
2.0 mg/L ± 10% At least
10,000 particles/mL
50% reduction
85% reduction
97.2%
99.5%
Contaminant Reduction Inuent Challenge
Concentration
Maximum Permissible
Product Water Concentration
Average%Reduction
Lead: @ pH 6.5 / @ pH 8.5 0.15 mg/L± 10% 0.010 mg/L >99.3% / 98.6%
Benzene 0.015 mg/L ± 10% 0.005 mg/L 96.0%
p - Dichlorobenzene 0.225 mg/L ± 10% 0.075 mg/L >99.8%
Carbofuran 0.08 mg/L ± 10% 0.040 mg/L 91.9%
Toxaphene 0.015 ± 10% 0.003 mg/L 93.3%
Atrazine 0.009 mg/L ± 10% 0.003 mg/L 92.4%
Asbestos 10
7
to 10
8
bers/L
††
99% >99%
Live Cysts
50,000/L min. 99.95% >99.99%
Turbidity 11 NTU ± 10% 0.5 NTU 99.0%
Lindane 0.002 ± 10% 0.0002 mg/L 98.9%
Tetrachloroethylene 0.015 mg/L ± 10% 0.005 mg/L >96.6%
O-Dichlorobenzene 1.8 mg/L ± 10% 0.60 mg/L >99.9%
Ethylbenzene 2.1 mg/L ± 10% 0.70 mg/L 99.4%
1,2,4-Trichlorobenzene 0.210 mg/L ± 10% 0.07 mg/L >99.8%
2,4 - D 0.210 mg/L ± 10% 0.07 mg/L 93.8%
Styrene 2.0 mg/L ± 10% 0.1 mg/L 99.8%
Toluene 3.0 mg/L ± 10% 1.0 mg/L 87.9%
Endrin 0.006 mg/L ± 10% 0.002 mg/L >96.6%
Atenolol 200 ± 20% 30 ng/L >95.9%
Trimethoprim 140 ± 20% 20 ng/L >96.9%
Linuron 140 ± 20% 20 ng/L >96.4%
Estrone 140 ± 20% 20 ng/L >97.0%
Nonylphenol 1400 ± 20% 200 ng/L >97.4%
Carbamazepine 1400 ± 20% 200 ng/L >97.9%
Phenytoin 200 ± 20% 30 ng/L 93.8%
Naproxen 140 ± 20% 20 ng/L 96.1%
Bisphenol A 2000 ± 20% 300 ng/L >99.2%
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.6 gpm (2.27 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
The compounds certied under NSF 401 have been deemed as “emerging compounds/incidental contaminants.” Emerging compounds/
incidental contaminants are those compounds that have been detected in drinking water supplies at trace levels. While occurring at only
trace levels, these compounds can affect the public acceptance/perception of drinking water quality.
System tested and certied by NSF International