Klarstein Crossfire - Connecting a Gas Cartridge

Klarstein Crossfire
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
EN
CONNECTING A GAS CARTRIDGE
This appliance is only suitable for use with low-pressure butane-propane mix gas and
tted with the appropriate low-pressure regulator via a exible hose. (Regulator certied
to BSEN 16129:2013). lf the regulator seals are missing or leaking, it is prohibited
to continue to use. Check the seals before connecting a new gas cartridge to the
appliance.
1. Open the back door, turn the
regulator switch knob clockwise
"-" to min position.
2. Turn gas cartridge clockwise to connect the gas
pressure-valve regulator.
3. Turn the regulator switch knob anticlockwise
"+" to max position to open the gas and turn
the regulator switch knob clockwise "-" to min
position to close the gas.
4. To change the gas-cartridges, turn the regulator
switch knob clockwise "-" to min position and
then turn empty gas cartridge anticlockwise to
disconnect from gas regulator.
IMPORTANT: Cartridges must be stored outdoors in an upright position and out of the
reach of children. The cartridge must never be stored where temperatures can reach
over 50 °C. Do not store the cartridge near ames or other sources of heat.