Nexus 105 DC Sounder & Sounder-Beacon
Installation Instructions
EN DE
FR
NL ES
PT IT
PL
SE DK
Texecom Ltd (Incorporating Klaxon Signals)
St Crispin Way, Haslingden, BB4 4PW, UK
Tel: +44 (0)1706 233879
(June 2013) 18-186456-9
Copyright © Texecom Ltd
email: sales@klaxonsignals.com www.klaxonsignals.com
Tone Tone Type Tone Description /Application Dip Switch
(S1/S2)
3rd Stage
Tone
Peak Sound
Level
(dBA @1m, 24-V DC)
Sounder
Current
(mA Avg, 24V DC)
1. 970Hz (BS5839-1:2002) O-O-O-O-O-O 18 105 31
2 800Hz/970Hz @ 2Hz (BS5839-1:2002) O-O-O-O-O-I 1 105 28
3 800Hz – 970Hz @ 1Hz (BS5839-1:2002) O-O-O-O-I-O 1 104 25
4 970Hz 1s OFF/1s ON (Apollo Fire Systems Alert Tone, BS5839-1:2002) O-O-O-O-I-I 1 105 17
5 970Hz, 0.5s/ 630Hz, 0.5s (Apollo Fire Systems Evacuate Tone, BS5839-1:2002) O-O-O-I-O-O 1 105 27
6 554Hz, 0.1s/ 440Hz, 0.4s (France – AFNOR NF S 32 001 ) O-O-O-I-O-I 1 103 20
7 500 – 1200Hz, 3.5s/ 0.5s OFF (Netherlands – NEN 2575:2000 Dutch Slow Whoop) O-O-O-I-I-O 1 108 19
8 420Hz 0.625s ON/0.625s OFF (Australia AS1670 Alert tone) O-O-O-I-I-I 1 102 10
9 500 – 1200Hz, 0.5s/ 0.5s OFF x 3/1.5s OFF (Australia AS1670 Evacuation tone) O-O-I-O-O-O 1 106 13
10 550Hz/440Hz @ 0.5Hz O-O-I-O-O-I 19 104 21
11 970Hz, 0.5s ON/0.5s OFF x 3/ 1.5s OFF (ISO 8201 Low tone) O-O-I-O-I-O 1 105 13
12 2850Hz, 0.5s ON/0.5s OFF x 3/1.5s OFF (ISO 8201 High tone) O-O-I-O-I-I 1 107 16
13 1200Hz – 500Hz @ 1Hz (DIN 33 404) O-O-I-I-O-O 1 109 22
14 400Hz O-O-I-I-O-I 18 101 16
15 550Hz, 0.7s/1000Hz, 0.33s O-O-I-I-I-O 1 105 25
16 1500Hz – 2700Hz @ 3Hz (Vandal Alarm) O-O-I-I-I-I 1 113 32
17 Simulated Bell O-I-O-O-O-O 1 107 18
18 2130Hz O-I-O-O-O-I 1 110 26
19 660Hz O-I-O-O-I-O 10 102 25
20 660Hz 1.8s ON/1.8s OFF O-I-O-O-I-I 19 102 14
21 660Hz 0.15s ON/0.15s OFF O-I-O-I-O-O 19 102 14
22 510Hz, 0.25s/ 610Hz, 0.25s O-I-O-I-O-I 1 103 24
23 800/1000Hz 0.5s each (1Hz) O-I-O-I-I-O 1 106 25
24 250Hz – 1200Hz @ 12Hz O-I-O-I-I-I 1 101 23
25 500Hz – 1200Hz @ 0.33Hz. O-I-I-O-O-O 1 108 21
26 2400Hz – 2900Hz @ 9Hz O-I-I-O-O-I 1 113 39
27 2400Hz – 2900Hz @ 3Hz O-I-I-O-I-O 1 111 39
28 800Hz – 970Hz @ 100Hz O-I-I-O-I-I 1 104 23
29 800Hz – 970Hz @ 9Hz O-I-I-I-O-O 1 104 27
30 800Hz – 970Hz @ 3Hz O-I-I-I-O-I 1 105 28
31 800Hz, 0.25s ON/1s OFF O-I-I-I-I-O 1 103 8
32 500Hz – 1200Hz, 3.75s/0.25s OFF (AS2220) O-I-I-I-I-I 1 108 20
33 340Hz I-O-O-O-O-O 1 101 17
34 1000Hz I-O-O-O-O-I 18 106 25
35 1400Hz – 1600Hz, 1s/1600Hz – 1400Hz, 0.5s (NF 48-265) I-O-O-O-I-O 1 104 34
36 660Hz 6.5s ON/13s OFF I-O-O-O-I-I 19 102 9
37 1000Hz/2000Hz, 1s each I-O-O-I-O-O 1 108 25
38 720Hz, 0.7s ON/0.3s OFF I-O-O-I-O-I 1 104 16
39 970Hz, 0.25s ON/OFF I-O-O-I-I-O 1 105 17
40 2800Hz, 1s ON/OFF I-O-O-I-I-I 1 106 20
41 2800Hz 0.25s ON/OFF I-O-I-O-O-O 1 106 19
42 2400/2900 @ 2Hz I-O-I-O-O-I 1 113 38
43 Chime, 554Hz/440Hz Single shot ‘ding dong’ I-O-I-O-I-O 1 100 15
44 Chime, 554Hz/440Hz Repeating ‘ding dong’ I-O-I-O-I-I 1 102 15
45 Chime, 970Hz/800Hz Single shot ‘ding dong’ I-O-I-I-O-O 1 101 36
46 Chime, 970Hz/800Hz Repeating ‘ding dong’ I-O-I-I-O-I 1 100 36
47 Hooter, Repeating I-O-I-I-I-O 1 102 13
48 Gentle alarm - Tone 2, rises slowly to full volume over 30s I-O-I-I-I-I 1 105 28
49 Time-Out Alarm – As Tone 2, cuts off after 10 mins I-I-O-O-O-O 1 105 28
50 Time-Out Alarm – As Tone 2, cuts off after 2 mins I-I-O-O-O-I 1 105 28
51 750Hz 0.33s ON/0.51s OFF I-I-O-O-I-O 1 103 8
52 750Hz 0.51s ON/0.33s OFF I-I-O-O-I-I 1 103 15
53 550Hz, 0.33s/1000Hz, 0.7s I-I-O-I-O-O 1 106 25
54 600Hz – 900Hz/ 0.9s I-I-O-I-O-I 1 104 31
55 660Hz – 680Hz/ 0.9s I-I-O-I-I-O 1 101 28
56 670Hz – 725Hz/ 0.9s I-I-O-I-I-I 1 104 25
57 920Hz – 750Hz/ 0.9s I-I-I-O-O-O 1 104 30
58 700Hz - 900Hz, 0.3s/0.6s OFF I-I-I-O-O-I 1 104 11
59 900Hz - 760Hz, 0.6s/0.3s OFF I-I-I-O-I-O 1 105 19
60 750Hz I-I-I-O-I-I 18 103 22
61 Power Only – Use with Stage 3 control for manual/intermittent chime triggering I-I-I-I-O-O 43
62 Power Only – Use with Stage 3 control for manual/intermittent chime triggering I-I-I-I-O-I 43
63 Power Only – Use with Stage 3 control for manual/intermittent horn triggering I-I-I-I-I-O 47
EN54-3:2001+A1
Fire Alarm Device – Sounder
Type B: For indoor or outdoor use
PNS-0001/PNC-0001/02/20/41/43/24/28/45/46/47
Technical Data: Document 18-186528
Question and Answer IconNeed help?

Do you have a question about the Klaxon Nexus 105 and is the answer not in the manual?

Klaxon Nexus 105 Specifications

General IconGeneral
BrandKlaxon
ModelNexus 105
CategoryMarine Equipment
LanguageEnglish

Summary

Product Compliance and Data

EN54-3:2001+A1 Compliance

Specifies adherence to EN54-3:2001+A1 standards for fire alarm devices.

Technical Data

Lists key technical specifications and documentation reference for the sounder and beacon.

Installation Procedures

Wiring

Details external wiring connections for sounder and beacon units.

Controls

Explains setting alarm tones and adjusting volume via dipswitches and potentiometers.

Technical Specification

Provides detailed electrical and performance characteristics of the sounder and beacon.