TT-1617 12/13 9
10. Service Schedule
Perform Service at Intervals Indicated (X)
Before
Starting
After
50 Hr or
1 Month
Every
100 Hr or
3 Months
Every
300 Hr or
6 Months
Every
500 Hr or
Yearly
Fuel System
Check the fuel level and fill as necessary X
Check fuel lines and replace as necessary *[ X
Replace the fuel filter *[ X
Lubrication System
Check crankcase oil level and add as necessary X
Replace the oil in crankcase * X (200 hr)
Replace the lube oil filter element * X (200 hr)
Cooling System
Check coolant level and fill as necessary * X
Check seawater outlet and clean as necessary [
X (during
operation)
Check function of siphon break, if equipped X
Check and clean seawater flow switch * X
Replace seawater pump impeller *[ X
(check)
X
Adjust seawater pump tension *[ X (200 hr) X
Check heat exchanger anticorrosion zinc
condition *
X
Replace heat exchanger anticorrosion zinc * X
Flush cooling system * [
X (1000 hr/
2 years)
Ignition System
Check spark plugs condition and gap * X
Replace spark plugs * X (250 hr)
Intake/Exhaust System
Inspect exhaust system components *[
X
Check the exhaust gas condition
X (during
operation)
Service backfire flame arrestor * X
Check and/or replace the catalyst assembly *[
X
Replace the CO sensor module *[
X (every
2 years)
Check the crankcase breather pipe for obstructions *[
X
Inspect the complete exhaust system *** X
Electrical System
Keep battery charged and in good condition X
Check and tighten electrical connections * X
Clean battery cables [ X (200 hr)
Engine And Mounting
Check for water, fuel, coolant, and oil leakage *[] X
Retighten all nuts and bolts * X
Check tightness of mounting bolts/vibromounts * X (200 hr)
Remote Control System
Check remote control operation
X (break-in
period)
X
Generator
Test run generator set X (weekly)
Blow dust out of generator *[ X
Clean slip rings and inspect brushes *[ X (1000 hr .)
* Requires removal of sound shield, if installed. *** Should be performed by your local distributor/dealer.
[ Consult your local distributor/dealer for service.
Consult battery manufacturer’s instructions.
] Read WARNING found at the beginning of manual regarding moving parts.
Question and Answer IconNeed help?

Do you have a question about the Kohler 10EKD and is the answer not in the manual?

Kohler 10EKD Specifications

General IconGeneral
Fuel TypeDiesel
Frequency60 Hz
Power (kVA)10 kVA
Power Output8 kW
Engine Speed1800 RPM
Cooling SystemLiquid Cooled
Starting SystemElectric Start
PhaseThree-Phase

Summary

Safety Precautions

Disabling the Generator Set

Instructions on disabling the generator set before maintenance.

Hazardous Voltage and Moving Parts

Warnings regarding electrical hazards and dangerous moving parts.

Testing Live Electrical Circuits

Precautions for safely testing live electrical circuits.

Accidental Starting Prevention

Measures to prevent accidental generator set startup.

Replace Seawater Switches

Install Wiring Harness

Install Relay in Junction Box

Install Seawater Flow Switch

Run and Test Generator Set

Check for Water Leaks

Procedure to verify the absence of water leaks after installation.

Seawater Flow Switch Validation

Test to validate the operation and wiring of the seawater flow switch.

Seawater Pressure Switch Validation

Test to validate the operation and wiring of the seawater pressure switch.