EasyManua.ls Logo

Kohler 9EFKOZD

Kohler 9EFKOZD
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TP-6773 5/12a16 Section 3 Cooling System
3.2.5 Closed Heat Exchanger
A closed heat exchanger is the best cooling method for
most applications. See Figure 3-6 for a typical
installation. Provide space to access the water-cooled
exhaust manifold pressure cap.
Seawater
Freshwater (Coolant/Antifreeze)
1
2
8
10
9
11
12
7
6
5
4
3
1. Engine block
2. Thermostat
3. Engine-driven water pump
4. Engine-driven seawater pump
5. Seawater strainer (customer-supplied)
6. Seacock (customer-supplied)
7. Intake strainer (customer-supplied)
8. Water-cooled manifold
9. Exhaust mixer elbow
10. Heat exchanger (located inside manifold)
11. Silencer (customer-supplied)
12. Exhaust outlet (customer-supplied)
Figure 3-6 Typical Closed/Heat Exchanger Cooling System