Governor System
28 24 690 34 Rev. DKohlerEngines.com
Sensitivity Adjustment
Governor sensitivity is adjusted by repositioning
governor spring in holes of governor lever. If speed
surging occurs with a change in engine load, governor
is set too sensitive. If a big drop in speed occurs when
normal load is applied, governor should be set for
greater sensitivity and adjust as follows:
1. To increase sensitivity, move spring closer to
governor cross shaft.
2. To decrease sensitivity, move spring away from
governor cross shaft.