Install Oil Sentry
(if equipped)
1. Apply pipe sealant with Teon
®
(Loctite
®
PST
®
592™
Thread Sealant or equivalent) to threads of Oil
Sentry
switch and install it into breather cover.
Torque to 4.5 N·m (40 in. lb.).
2. Connect wire lead (green) to Oil Sentry
terminal.
Install Control Panel
1. Assemble choke lever to control bracket.
2. Install control panel to blower housing.
3. Assemble throttle control shaft to control bracket.
Secure throttle shaft bracket with screws to cylinder
head.
4. Connect choke control cable and throttle control
cable to control bracket.
Reconnect Rectier-Regulator
1. Install rectier-regulator in blower housing if removed
previously, then connect rectier-regulator ground
lead with washer and green screw through eyelet. If
a grounding bracket is used, secure with mounting
screw and washer, against outer side of rectier-
regulator.
2. Install B+ terminal/lead into center position of
rectier-regulator plug and connect plug to rectier-
regulator.
Install Valve Covers
Torque Sequence
24
1
3
1. Make sure sealing surfaces are clean.
2. Make sure there are no nicks or burrs on sealing
surfaces.
3. Install a new O-ring in groove of each cover.
4. Position covers on cylinder heads. Locate cover with
oil separator hole on cylinder 1. Install four screws in
each cover and nger tighten.
5. Torque valve cover fasteners to 6.2 N·m (55 in. lb.)
using sequence shown.
6. Install rubber grommet into cylinder 1 valve cover.
Install oil separator into grommet and secure to
blower housing with mounting screws.