8 37 590 02 Rev. BKohlerPower.com
5. Check sediment bowl cover and gasket. 
Replace them if they are damaged.
6. Reinstall sediment bowl.
7. Open tank fuel valve (R).
8. Wipe off any trace of fuel with a clean cloth 
and check for any leakage.
Spark Plugs
 CAUTION
Electrical Shock can cause injury.
Do not touch wires while 
generator is running.
Never operate generator in rain or snow.
Never touch generator with wet hands or 
electrical shock may occur.
Clean out spark plug recess. Remove spark 
plug (K) and replace.
1. Check gap using wire feeler gauge. Adjust 
gap, see specifi cation table for adjustment.
2. Install spark plug (K) into cylinder head.
3. Torque spark plug (K) to 20 ft. lb. (27 N·m).
Air Cleaner
NOTE:  Operating engine with loose or 
damaged air cleaner components 
could cause premature wear and 
failure. Replace all bent or damaged 
components.
1. Remove screw (N) and air cleaner cover (O).
2. Remove foam element (P) from air cleaner 
base (Q).
3. Wash foam element (P) in warm water with 
detergent. Rinse and allow to air dry.
4. Lightly oil foam element (P) with new engine 
oil; squeeze out excess oil.
5. Reinstall foam element (P) into air cleaner 
base (Q).
6. Reinstall air cleaner cover (O) and secure 
with screw (N).
Breather Tube
Ensure both ends of breather tube are properly 
connected.
Fuel Level
 WARNING
Explosive Fuel can cause fi res 
and severe burns.
Do not fi ll fuel tank while 
generator is hot or running.
Gasoline is extremely fl ammable and 
its vapors can explode if ignited. Store 
gasoline only in approved containers, in 
well ventilated, unoccupied buildings, away 
from sparks or fl ames. Spilled fuel could 
ignite if it comes in contact with hot parts or 
sparks from ignition. Never use gasoline as a 
cleaning agent.
Visually check level of fuel. If necessary, fi ll up.
1. Unscrew fuel tank cap (F).
2. Fill tank until fuel gauge shows F, using 
funnel and taking care not to spill any fuel.
3. Screw down fuel tank cap (F) tightly.
Fuel Line
Low permeation fuel line must be installed on 
carbureted Kohler Co. engines to maintain EPA 
and CARB regulatory compliance.
Fuel Filter
1. Open fuel tank cap (F).
2. Remove fuel fi lter (S) from tank neck.
3. Clean fuel fi lter (S) with a non-fl ammable 
solvent or solvent with a high fl ash point. Dry 
it fully. Replace as necessary.
4. Reinstall fuel fi lter (S).
5. Reinstall fuel tank cap (F).
Sediment Bowl
1. Close fuel valve (R) and remove cover 
screws and nuts.
2. Remove cover.
3. Remove sediment bowl.
4. Clean sediment bowl with a non-fl ammable 
solvent or solvent with a high fl ash point. Dry 
it fully.