Adjust the Water Level
Adjust the tank water level to the marked waterline.
Rotate the threaded rod clockwise to raise the water level or
counterclockwise to lower the water level as needed.
Periodically check for leaks for several days following the
installation.
Troubleshooting Guide
Troubleshooting Tips
NOTE: This troubleshooting guide is for general aid only. For
warranty service, contact your dealer or wholesale distributor.
Troubleshooting Table
Symptoms Recommended Action
1. Poor flush. A. Adjust the tank water level to match the
waterline.
B. Fully open the water supply shut-off
valve.
C. Clear obstructions from the trapway, jet, or
bowl rim holes.
D. Clear obstructions in the soil pipe or vent
pipe.
Threaded Rod
Water
Line